The ProSealTM laryngeal mask airway in children
Authors:
- 22 February 2005
- journal article
- research article
- Published by Wiley in Pediatric Anesthesia
- Vol. 15 (3) , 229-234
Abstract
Summary: Background : The ProSealTM (PLMA) is a new laryngeal mask device with a modified cuff to improve the seal and a drain tube to provide access to the gastrointestinal tract. We assessed the performance of the size 2 (which has no dorsal cuff) and size 3 (which has a dorsal cuff) in terms of insertion success, efficacy of seal, tidal volume, gas exchange, fiberoptic position, gastric tube placement and frequency of problems.Methods : Eighty children undergoing minor surgery were studied (n = 40, size 2 PLMA, weight 10–25 kg; n = 40, size 3 PLMA, weight >25–50 kg). Induction was with remifentanil and propofol. Insertion was with the introducer tool and by experienced users. Maintenance was with propofol or sevoflurane and pressure controlled ventilation.Results : The first‐time and overall insertion success rate was 84 and 100%, respectively. Oropharyngeal leak pressure was 31 ± 5 cmH2O. There were no gastric or drain tube air leaks. Tidal volume and gas exchange was adequate in all patients, other than two brief episodes of hypoxia because of airway reflex activation. The vocal cords and epiglottis were visible in 99 and 80%, respectively, via the airway tube. The first‐time and overall insertion success rate for gastric tube insertion was 87 and 100%, respectively. During maintenance, the PLMA was removed in one patient with airway reflex activation and another required epinephrine for bronchospasm. There were no differences in performance between the sizes 2 and 3 PLMA.Conclusion : The PLMA is an effective airway device in children and isolates the glottis from the esophagus when correctly positioned. Despite the lack of a dorsal cuff, the performance of the size 2 was similar to the size 3 PLMA in the age groups tested.Keywords
This publication has 29 references indexed in Scilit:
- A Comparison of the Laryngeal Mask Airway ProSeal™ and the Laryngeal Tube Airway in Paralyzed Anesthetized Adult Patients Undergoing Pressure-Controlled VentilationAnesthesia & Analgesia, 2002
- A Multicenter Study Comparing the ProSeal TMand Classic TMLaryngeal Mask Airway in Anesthetized, Nonparalyzed PatientsAnesthesiology, 2002
- Pressure versus volume‐controlled ventilation with a laryngeal mask airway™ in paediatric patientsPediatric Anesthesia, 2001
- A comparison of four methods for assessing oropharyngeal leak pressure with the laryngeal mask airway (LMA™) in paediatric patientsPediatric Anesthesia, 2001
- A Fibreoptic Scoring System to Assess the Position of Laryngeal Mask Airway Devices. Interobserver Variability and a Comparison Between the Standard, Flexible and Intubating Laryngeal Mask AirwaysAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 2000
- The ProSeal Laryngeal Mask AirwayAnesthesiology, 2000
- Usefulness of self made introducer for laryngeal mask airway in paediatric anaesthesiaPediatric Anesthesia, 1997
- Safety and efficacy of the laryngeal mask airway A prospective survey of 1400 childrenAnaesthesia, 1996
- Laryngeal mask insertion with a laryngoscope in paediatric patientsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1996
- The laryngeal mask airway in childrenAnaesthesia, 1991