Determination of lithium in human serum by isotope dilution atomic absorption spectrometry
Authors:
Open Access
- 10 September 2021
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (1) , 251-256
Abstract
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry. Graphical abstractKeywords
All Related Versions
Funding Information
- Bundesanstalt für Materialforschung und -prüfung (BAM)
This publication has 30 references indexed in Scilit:
- Review of Lithium Effects on Brain and BloodCell Transplantation, 2009
- Isotope dilution strategies for absolute quantitative proteomicsJournal of Proteomics, 2009
- Characterisation of reference materials by isotope dilution mass spectrometryJournal of Analytical Atomic Spectrometry, 2007
- Experimental design optimization for the ICP-AES determination of Li, Na, K, Al, Fe, Mn and Zn in human serumJournal of Pharmaceutical and Biomedical Analysis, 2007
- Metal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hairForensic Science International, 2005
- Determination of Lithium Contents in Silicates by Isotope Dilution ICP‐MS and its Evaluation by Isotope Dilution Thermal Ionisation Mass SpectrometryGeostandards and Geoanalytical Research, 2004
- Uncertainty in SI-traceable measurements of amount of substance by isotope dilution mass spectrometryMetrologia, 2000
- Lithium neurotoxicity?the reliability of serum lithium measurementsHuman Psychopharmacology: Clinical and Experimental, 1990
- Accurate assay of lithium by isotope dilution mass spectrometry.International Journal of Mass Spectrometry and Ion Physics, 1983
- Determination of lithium by optically monitored stable isotope dilutionAnalytical Chemistry, 1979