Validation of Varian's AAA algorithm with focus on lung treatments
- 1 January 2009
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 48 (2) , 209-215
Abstract
The objective of this study was to examine the accuracy of the Anisotropic Analytical Algorithm (AAA). A variety of different field configurations in homogeneous and in inhomogeneous media (lung geometry) was tested for the AAA algorithm. It was also tested against the present Pencil Beam Convolution (PBC) algorithm. Two dimensional (2D) dose distributions were measured for a variety of different field configurations in solid water with a 2D array of ion chambers. The dose distributions of patient specific treatment plans in selected transversal slices were measured in a Thorax lung phantom with Gafchromic dosimetry films. A Farmer ion chamber was used to check point doses in the Thorax phantom. The 2D dose distributions were evaluated with a gamma criterion of 3% in dose and 3 mm distance to agreement (DTA) for the 2D array measurements and for the film measurements. For AAA, all fields tested in homogeneous media fulfilled the criterion, except asymmetric fields with wedges and intensity modulated plans where deviations of 5 and 4%, respectively, were seen. Overall, the measured and calculated 2D dose distributions for AAA in the Thorax phantom showed good agreement -- both for 6 and 15 MV photons. More than 80% of the points in the high dose regions met the gamma criterion, though it failed at low doses and at gradients. For the PBC algorithm only 30-70% of the points met the gamma criterion. The AAA algorithm has been shown to be superior to the PBC algorithm in heterogeneous media, especially for 15 MV. For most treatment plans the deviations in the lung and the mediastinum regions are below 3%. However, the algorithm may underestimate the dose to the spinal cord by up to 7%.Keywords
This publication has 17 references indexed in Scilit:
- The impact of photon dose calculation algorithms on expected dose distributions in lungs under different respiratory phasesPhysics in Medicine & Biology, 2008
- Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapyMedical Physics, 2007
- On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculationsPhysics in Medicine & Biology, 2007
- Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planningRadiotherapy and Oncology, 2006
- Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetryPhysics in Medicine & Biology, 2006
- Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situationsPhysics in Medicine & Biology, 2006
- Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in waterPhysics in Medicine & Biology, 2006
- A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations*Physics in Medicine & Biology, 2005
- Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam dataPhysics in Medicine & Biology, 1996
- Calculation models for determining the absorbed dose in water phantoms in off-axis planes of rectangular fields of open and wedged photon beamsPhysics in Medicine & Biology, 1995