Simultaneous determination of phthalates and bisphenols from plastic bottled water samples by dispersive solid‐phase extraction with multiwalled carbon nanotubes and liquid chromatography/atmospheric pressure photoionization/high‐resolution mass spectrometry
- 27 September 2022
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 36 (23) , e9394
Abstract
Rationale: Phthalates and bisphenols were reported as endocrine disrupting chemicals and hence a potential threat to human health. Polyethylene terephthalate bottles are being used to store drinking water and the probability of migration of phthalates and bisphenols from the bottles into the water is high. The migration of analytes with respect to different storage conditions need to be studied. Method: A sensitive analytical method for simultaneous determination of seven phthalates and three bisphenols from packaged drinking water was developed using liquid chromatography/atmospheric pressure photoionization/high‐resolution mass spectrometry. The analytes were extracted by dispersive solid‐phase extraction by multiwalled carbon nanotubes. Results: The developed method showed linearity from 0.5 to 5000 μg/L with the limit of detection and limit of quantification ranging from 0.5 to 1 μg/L and 1 to 2 μg/L, respectively, for phthalates and bisphenols. The inter‐ and intraday variations were below 10%. The recoveries were in the range of 79.5% to 112%. The migration of phthalates and bisphenols increased with storage time and temperature. Maximum migration was observed for diisobutyl phthalate of 1209.7 ng/L followed by dibutyl phthalate at 777.8 ng/L on 180 days of analysis at room temperature. Migration of bis(2‐ethylhexyl) phthalate was observed to be higher at elevated temperatures, increasing from 14.9 to 514 ng/L. Similarly, migration of bisphenol‐A was increased at 45°C. The results were subjected to analysis of variance (ANOVA) studies and the results showed significant variations of phthalates and bisphenols with respect to storage temperature and time. Conclusion: The use of atmospheric pressure photoionization facilitated simultaneous determination of phthalates and bisphenols. The migration of phthalates and bisphenols increased with increasing temperature and storage time. Maximum migration was observed for diethyl, diisobutyl, dibutyl and bis(2‐ethylhexyl) phthalates. This may be attributed to the type of plastic, the processing parameters and recycling.Keywords
This publication has 33 references indexed in Scilit:
- Determination of Phthalates in Jordanian Bottled Water using GC–MS and HPLC–UV: Environmental StudyJournal of Chromatographic Science, 2013
- Occurrence and Profiles of Phthalates in Foodstuffs from China and Their Implications for Human ExposureJournal of Agricultural and Food Chemistry, 2012
- Preparation of magnetic core mesoporous shell microspheres with C18-modified interior pore-walls for fast extraction and analysis of phthalates in water samplesJournal of Chromatography A, 2011
- Plastics and Health RisksAnnual Review of Public Health, 2010
- Study on the migration of bisphenol‐A from baby bottles by stir bar sorptive extraction‐thermal desorption‐capillary GC‐MSJournal of Separation Science, 2009
- Considerations on ultra-trace analysis of phthalates in drinking waterWater Research, 2006
- Advantages of atmospheric pressure photoionization mass spectrometry in support of drug discoveryRapid Communications in Mass Spectrometry, 2005
- European survey of contamination of homogenized baby food by epoxidized soybean oil migration from plasticized PVC gasketsFood Additives & Contaminants, 2003
- Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatographyAnalytica Chimica Acta, 2003
- Investigations into the potential degradation of polycarbonate baby bottles during sterilization with consequent release of bisphenol AFood Additives & Contaminants, 1997