Validity of Values for Metabolic Equivalents of Task During Submaximal All-Extremity Exercise and Reliability of Exercise Responses in Frail Older Adults
Open Access
- 1 June 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 88 (6) , 747-756
Abstract
Background and Purpose: Physical therapists and rehabilitation professionals in hospital and long-term care centers are using all-extremity semirecumbent exercise machines in their treatment programs. This study was undertaken to investigate the concurrent validity of values for software-generated metabolic equivalents of task (MET) from an all-extremity semirecumbent exercise machine and directly measured values for MET from a portable metabolic unit across a range of submaximal exercise intensities. A second purpose of this study was to determine the test-retest reliability of oxygen consumption and heart rate responses in older adults between standardized sessions of submaximal all-extremity aerobic exercise.Subjects and Methods: The study participants were 18 older adults (mean age=82 years, SD=5; 3 women, 15 men) who were living in long-term care centers and who completed 2 test sessions of a standardized exercise protocol 1 week apart. The exercise protocol included a warm-up period, three 4-minute stages of exercise at incremental workload levels, and a cool-down period. The breath-by-breath metabolic data from the portable metabolic unit, heart rate, MET values from the exercise machine, Borg Rating of Perceived Exertion, and watts were recorded continuously throughout the exercise protocol.Results: The concurrent validity of the MET values from the exercise machine and the portable metabolic unit ranged from very good to excellent on both day 1 and day 2 (r=.85–.97). The test-retest reliability of subjects' heart rate responses and MET values from the portable metabolic unit was moderate to high across submaximal exercise intensities (intraclass correlation coefficients [2,1]=.85–.91).Discussion and Conclusion: The exercise machine software-generated MET values were representative of directly measured oxygen consumption values across a range of submaximal intensities during all-extremity semirecumbent exercise in older adults with multisystem impairments.Keywords
This publication has 24 references indexed in Scilit:
- A global clinical measure of fitness and frailty in elderly peopleCanadian Medical Association Journal, 2005
- Maximal Aerobic Capacity Testing of Older Adults: A Critical ReviewThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 2005
- Effects of physical training on physical performance in institutionalised elderly patients (70+) with multiple diagnosesAge and Ageing, 2003
- Effects of Aerobic Exercise Training in Community‐Based Subjects Aged 80 and Older: A Pilot StudyJournal of the American Geriatrics Society, 2002
- Effects of Exercise Training on Frailty in Community‐Dwelling Older Adults: Results of a Randomized, Controlled TrialJournal of the American Geriatrics Society, 2002
- Effects of Recumbent Stepper Exercise on Blood Pressure, Strength and Mobility in Residents of Assisted Living Communities: A Pilot StudyPhysical & Occupational Therapy In Geriatrics, 2002
- Frailty and Injuries in Later Life: The FICSIT TrialsJournal of the American Geriatrics Society, 1993
- The Mini‐Mental State Examination: A Comprehensive ReviewJournal of the American Geriatrics Society, 1992
- Targeting Strategies: An Overview of Criteria and OutcomesJournal of the American Geriatrics Society, 1991
- Falls and Injuries in Frail and Vigorous Community Elderly PersonsJournal of the American Geriatrics Society, 1991