FLAIR Vascular Hyperintensities/DWI Mismatch Predicts Penumbra in Proximal Middle Cerebral Artery Occlusion
- 1 April 2026
- journal article
- Published by Wolters Kluwer Health in Stroke
- Vol. 57 (4) , 982-991
Abstract
BACKGROUND: Perfusion imaging used to select patients for extended-window stroke therapy is not widely available. We investigated whether fluid-attenuated inversion recovery vascular hyperintensities (FVHs) on routine magnetic resonance imaging could serve as a reliable surrogate for perfusion imaging by predicting the mismatch between hypoperfused tissue volume (perfusion-weighted imaging [PWI]) and infarct core volume (diffusion-weighted imaging [DWI]) in patients with proximal middle cerebral artery occlusion. METHODS: We included, in a retrospective Bordeaux Hospital study (2021–2022), 200 consecutive proximal middle cerebral artery occlusion patients and developed 2 semiquantitative scoring systems—FVH -c-ASPECTS (cortical-Alberta Stroke Program Early Computed Tomography Score) and DWI -c-ASPECTS —based on the 7 c-ASPECTS regions. We assessed the correlation between the FVH/DWI -c-ASPECTS ratio and the true PWI/DWI mismatch and analyzed its association with 24-hour and 3-month outcomes. Predictive performance for the PWI/DWI ratio was tested using the area under the curve–receiver operating characteristic curve. Two thresholds were evaluated—the cohort median PWI/DWI ratio and PWI/DWI ≥1.8 with mismatch >15 mL in patients imaged ≥6 hours after onset—and sensitivity, specificity, positive and negative predictive value with 95% CIs were calculated. RESULTS: The FVH/DWI -c-ASPECTS ratio strongly correlated with the PWI/DWI mismatch ( ρ =0.77; P 15 mL (area under the curve, 0.92 [95% CI, 0.84–1.00]; sensitivity, 97.8%; specificity, 73.3%; positive predictive value, 91.8%; and negative predictive value, 91.7%). The FVH/DWI -c-ASPECTS ratio was independently associated with early major neurological improvement, 24-hour National Institutes of Health Stroke Scale score decrease ≥8 or at 0 to 1 (odds ratio, 1.31; P =0.004) and inversely associated with hemorrhagic transformation ( P =0.002). CONCLUSIONS: The FVH/DWI -c-ASPECTS ratio is a potential surrogate imaging marker of perfusion-diffusion mismatch in patients with proximal middle cerebral artery occlusion. It may offer a practical and widely accessible alternative to perfusion imaging for identifying candidates for reperfusion therapy beyond the standard time window.Keywords
This publication has 45 references indexed in Scilit:
- Added assessment of middle cerebral artery and atrial fibrillation to FLAIR vascular hyperintensity-DWI mismatch would improve the outcome prediction of acute infarction in patients with acute internal carotid artery occlusionNeurological Sciences, 2019
- Benefit from revascularization after thrombectomy according to FLAIR vascular hyperintensities–DWI mismatchEuropean Radiology, 2019
- Fluid-Attenuated Inversion Recovery Vascular HyperintensityArchives of Neurology, 2012
- Magnetic resonance imaging versus computed tomography for detection of acute vascular lesions in patients presenting with stroke symptomsCochrane Database of Systematic Reviews, 2009
- Hypertension and Cerebrovascular DysfunctionCell Metabolism, 2008
- Thrombolysis with alteplase for acute ischaemic stroke in the Safe Implementation of Thrombolysis in Stroke-Monitoring Study (SITS-MOST): an observational studyThe Lancet, 2007
- Magnetic resonance imaging and computed tomography in emergency assessment of patients with suspected acute stroke: a prospective comparisonThe Lancet, 2007
- Statin use is associated with enhanced collateralization of severely diseased coronary arteriesAmerican Heart Journal, 2003
- Statins induce angiogenesis, neurogenesis, and synaptogenesis after strokeAnnals of Neurology, 2003
- Validity and reliability of a quantitative computed tomography score in predicting outcome of hyperacute stroke before thrombolytic therapyThe Lancet, 2000