Comparison of Intraocular Pressure During Corneal Flap Preparation Between a Femtosecond Laser and a Mechanical Microkeratome in Porcine Eyes
Authors:
- Jan Markus VetterJVJan Markus Vetter
- Astrid SchirraASAstrid Schirra
- David Garcia-BardonDGDavid Garcia-Bardon
- Katrin LorenzKLKatrin Lorenz
- Wolf E WeingärtnerWWWolf E Weingärtner
- Walter SekundoWSWalter Sekundo
- 1 October 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 30 (10) , 1150-1154
Abstract
To compare the increase in intraocular pressure (IOP) during corneal flap preparation in porcine eyes when using a femtosecond laser or a mechanical microkeratome. The present study was conducted at a university hospital and a private clinic. The vitreous IOP was directly measured with a cannula through the optic nerve in 24 porcine globes (n = 12 for each device). In the first procedure (worst-case procedure), the eye interface was lowered against the globe until abortion of the docking maneuver when using the IntraLase femtosecond laser (Abbott Medical Optics, Santa Ana, CA) or the suction ring was pressed very firmly against the globe when using the Amadeus microkeratome (Ziemer Ophthalmic Systems AG, Port, Switzerland). In the second procedure (regular procedure), a normal lamellar flap creation was performed using each of these devices. During the worst-case procedure, a maximum IOP of 260 ± 53 mm Hg (mean ± SD) was reached with the IntraLase and 318 ± 59 mm Hg was reached with the Amadeus. During the regular procedure, the maximum IOP increased to 135 ± 16 mm Hg when using the IntraLase femtosecond laser and to 152 ± 24 mm Hg with the Amadeus microkeratome. In the worst-case procedure, the maximum IOP levels were lower in the IntraLase group. No significant difference in maximum IOP levels could be obtained during the regular procedure. The duration of the suction phase is longer when using the IntraLase femtosecond laser.Keywords
This publication has 21 references indexed in Scilit:
- Corneal Aberrations and Visual Acuity After Laser In Situ Keratomileusis: Femtosecond Laser Versus Mechanical MicrokeratomeAmerican Journal of Ophthalmology, 2010
- Early onset of Rhegmatogenous retinal detachment after LASIK with femtosecond laserJapanese Journal of Ophthalmology, 2009
- Acute rhegmatogenous retinal detachment immediately following laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2007
- Porcine Model to Compare Real-Time Intraocular Pressure during LASIK with a Mechanical Microkeratome and Femtosecond LaserInvestigative Ophthalmology & Visual Science, 2007
- Visual Experiences During Different Stages of LASIK: Zyoptix XP Microkeratome vs Intralase Femtosecond LaserAmerican Journal of Ophthalmology, 2007
- Avoidance, Recognition, and Management of LASIK ComplicationsAmerican Journal of Ophthalmology, 2006
- Macular hemorrhage after laser in situ keratomileusis (LASIK) with femtosecond laser flap creationAmerican Journal of Ophthalmology, 2004
- Proposed mechanism for retinal tears after LASIKOphthalmology, 2004
- Laser in situ keratomileusis for myopia and astigmatism: safety and efficacyOphthalmology, 2002
- LASIKCornea, 1998