Visual Comparison of Multifocal Contact Lens to Monovision
- 1 February 2009
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 86 (2) , E98-105
Abstract
Purpose.: To compare visual function with the Bausch & Lomb PureVision multifocal contact lens to monovision with PureVision single vision contact lenses. Methods.: Twenty presbyopic subjects were fitted with either the PureVision multifocal contact lens or monovision with PureVision single vision lenses. After a 1‐month trial, the following assessments of visual function were made: (a) distance, intermediate, and near visual acuity (VA); (b) reading ability; (c) distance and near contrast sensitivity function (CSF); (d) near range of clear vision; (e) stereoacuity; and (f) subjective evaluation of near vision ability with a standardized questionnaire. Subjects were then refitted with the alternative correction and the procedure was repeated. All measurements were compared between the two corrections, whereas the “low addition” multifocal lens was also compared with the “high addition” alternative. Results.: Distance and near VA were significantly better with monovision than with the multifocal option (p < 0.05). Intermediate VA (p = 0.13) was similar with both corrections, whereas there was also no significant difference in distance and near CSF (p = 0.29 on both occasions). Reading speeds (p = 0.48) and the critical print size (p = 0.90) were not significantly different between the two contact lens corrections, but stereoacuity (p < 0.01) and the near range of clear vision (p < 0.05) were significantly better with the multifocal option than with monovision. Subjective assessment of near ability was similar for both types of contact lens (p = 0.52). The high addition multifocal lens produced significantly poorer distance and near CSF, near VA, and critical print size compared with the low addition alternative. Conclusions.: Monovision performed better than a center‐near aspheric simultaneous vision multifocal contact lens of the same material for distance and near VA only. The multifocal option provides better stereoacuity and near range of clear vision, with little differences in CSF, so a better balance of real‐world visual function may be achieved due to minimal binocular disruption.Keywords
This publication has 26 references indexed in Scilit:
- Monovision: a reviewOphthalmic and Physiological Optics, 2007
- Development of a near activity visual questionnaire to assess accommodating intraocular lensesContact Lens and Anterior Eye, 2007
- Is randomisation necessary for measuring defocus curves in pre-presbyopes?Contact Lens and Anterior Eye, 2007
- A decade of contact lens prescribing trends in the United Kingdom (1996–2005)Contact Lens and Anterior Eye, 2006
- Associations of Presbyopia With Vision-Targeted Health-Related Quality of LifeArchives of Ophthalmology (1950), 2003
- Repeatability and Intercorrelations of Standard Vision Tests as a Function of AgeOptometry and Vision Science, 2000
- Repeatability of Visual Acuity MeasurementOptometry and Vision Science, 1998
- Success of monovision in presbyopes: Review of the literature and potential applications to refractive surgerySurvey of Ophthalmology, 1996
- Does the Presbyopic Visual System Adapt to Contact Lenses?Optometry and Vision Science, 1993
- A New Contrast Sensitivity Vision Test ChartOptometry and Vision Science, 1984