Miniaturized Ultraviolet Ozonesonde for Atmospheric Measurements
Authors:
- 1 September 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (17) , 3059-3062
Abstract
The design and test results of a simple single-beam ultraviolet photometer for ozone measurements are presented. The instrument has several features that distinguish it from former UV absorption instruments, all of which contribute to a smaller size and much lower power consumption while retaining the advantages of the UV measurement technique. A novel airflow system and advanced electronics are among the most important changes from earlier reported systems. The instrument fits into a package 10 cm in diameter by 60 cm long and weighs under 1.5 kg. Hence, it is well-suited for lightweight airborne applications using kites and balloons, as well as other portable measurement needs. Independent measurements of ozone are made every 4 s, with a sensitivity of 0.3 ppbv ozone (limit of detection for S/N = 3) and a precision of ±2%.Keywords
This publication has 4 references indexed in Scilit:
- VERTICAL PROFILING OF THE ATMOSPHERE USING HIGH-TECH KITESEnvironmental Science & Technology, 1994
- Ozone profiling using kitesNature, 1994
- Electrochemical concentration cell ozonesonde accuracy and precisionJournal of Geophysical Research: Atmospheres, 1985
- Fast-response dual-beam UV-absorption ozone photometer suitable for use on stratospheric balloonsReview of Scientific Instruments, 1983