The measurement of rapid surface temperature fluctuations during nucleate boiling of water
Authors:
- 1 December 1961
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 7 (4) , 620-624
Abstract
The surface temperature during nucleate boiling was measured with a special thermocouple so designed as to measure the temperature of a small area and to have an extremely rapid response time. The surface temperature was found to drop occasionally 20° to 30°F. in about 2 msec. during the boiling of water. This indicates a rapid extraction of heat during a short time interval. The significance of this observation is that it provides an important new clue to an understanding of nucleate boiling. A hypothesis is advanced to explain these observations.Keywords
This publication has 6 references indexed in Scilit:
- Generalized Correlation of Boiling Heat TransferJournal of Heat Transfer, 1959
- Heat Transfer to a Boiling Liquid—Mechanism and CorrelationsJournal of Heat Transfer, 1959
- Effect of superatmospheric pressures on nucleate boiling of organic liquidsAIChE Journal, 1958
- A Method of Correlating Heat-Transfer Data for Surface Boiling of LiquidsJournal of Fluids Engineering, 1952
- A Study of the Mechanism of Boiling Heat TransferTransactions of the American Society of Mechanical Engineers, 1951
- Surface Tension MeasurementAnalytical Chemistry, 1949