Abstract
Rankine and Brayton cycles are common energy conversion cycles and constitute the basis of a significant proportion of global electricity production. Even a seemingly marginal improvement in the efficiency of these cycles can considerably decrease the annual use of primary energy sources and bring a significant gain in power plant output. Recently, supercritical Brayton cycles using CO2 as the working fluid have attracted much attention, chiefly due to their high efficiency. As with conventional cycles, improving the compressor performance in supercritical cycles is major route to increasing the efficiency of the whole process. This paper numerically investigates the flow field and performance of a supercritical CO2 centrifugal compressor. A thermodynamic look-up table is coupled with the flow solver, and the look-up table is systematically refined to take into account the large variation of thermodynamic properties in the vicinity of the critical point. Effects of different boundary and operating conditions are also discussed. It is shown that the compressor performance is highly sensitive to the look-up table resolution as well as the operating and boundary conditions near the critical point. Additionally, a method to overcome the difficulties of simulation close to the critical point is explained.Keywords
This publication has 10 references indexed in Scilit:
- Numerical Investigation of the Flow Behavior Inside a Supercritical CO2 Centrifugal Compressor2016
- Issues in performance measurement of CO2 compressor near the critical pointApplied Thermal Engineering, 2016
- An Investigation of Real Gas Effects in Supercritical CO2 Centrifugal CompressorsJournal of Turbomachinery, 2015
- Computational Fluid Dynamic Simulation of a Supercritical CO2 Compressor Performance MapJournal of Engineering for Gas Turbines and Power, 2015
- CFD investigation of a centrifugal compressor derived from pump technology for supercritical carbon dioxide as a working fluidThe Journal of Supercritical Fluids, 2014
- Description and Test Results from a Supercritical CO2 Brayton Cycle Development Program2009
- Compressor Design for the Supercritical CO2 Brayton Cycle2004
- Real gas Brayton cycles for organic working fluidsProceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 2001
- A New Equation of State for Carbon Dioxide Covering the Fluid Region from the Triple-Point Temperature to 1100 K at Pressures up to 800 MPaJournal of Physical and Chemical Reference Data, 1996
- Two-equation eddy-viscosity turbulence models for engineering applicationsAIAA Journal, 1994