Controlled posterior condylar milling technique for unicompartmental knee arthroplasty minimises tibia resection during gap balancing: Short‐term clinical results
- 19 January 2024
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 32 (2) , 499-508
Abstract
Purpose: The purpose of this study was to demonstrate the clinical utility of controlled posterior condylar milling (CPCM) in gap balancing while minimally resecting the tibia during fixed‐bearing unicompartmental knee arthroplasty (UKA).Methods: This study is a retrospective cohort study. Patients who underwent medial UKA for isolated medial compartment osteoarthritis with a minimum follow‐up of 2 years were included. The patients were divided into two groups: the conventional group (n = 56) and the CPCM group (n = 66). In the CPCM group, the proximal tibia was resected at the level of the distal end of the subchondral bone. If the flexion gap was tighter than extension, the posterior condyle was additionally milled to adjust gap tightness. Standing knee X‐ray and scanogram were used to evaluate alignment and tibia resection amount. Range of motion (ROM) and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) scores were used to evaluate clinical outcomes.Results: The CPCM group showed significantly smaller tibia resection (3.6 ± 1.9 mm) compared to the conventional group (5.2 ± 2.7 mm) (p < 0.001). Postoperative ROM (133.0 ± 8.3°, 135.2 ± 7.2°, n.s.) and WOMAC (19.3 ± 13.6, 23.6 ± 17.7, n.s.) were not significantly different between the two groups. Postoperative periprosthetic fractures occurred in two patients in conventional group, while the CPCM group had no periprosthetic fractures.Conclusion: The CPCM technique may be a simple and useful intraoperative technique that can achieve minimal tibia resection and promising clinical outcomes while easily adjusting gap tightness between flexion and extension during medial fixed‐bearing UKA.Level of Evidence: Level III.Keywords
This publication has 39 references indexed in Scilit:
- A meta-analysis of unicompartmental knee arthroplasty revised to total knee arthroplasty versus primary total knee arthroplastyJournal of Orthopaedic Surgery and Research, 2018
- Medial joint line elevation of the tibia measured during surgery has a significant correlation with the limb alignment changes following medial unicompartmental knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2018
- The medial tibial joint line elevation over 5 mm restrained the improvement of knee extension angle in unicompartmental knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2017
- Conversion of a unicompartmental knee arthroplasty to a total knee arthroplastyThe Bone & Joint Journal, 2017
- Does 3-Dimensional In Vivo Component Rotation Affect Clinical Outcomes in Unicompartmental Knee Arthroplasty?The Journal of Arthroplasty, 2016
- Why Do Medial Unicompartmental Knee Arthroplasties Fail Today?The Journal of Arthroplasty, 2016
- Balancing UKA: overstuffing leads to high medial collateral ligament strainsKnee Surgery, Sports Traumatology, Arthroscopy, 2015
- Optimal usage of unicompartmental knee arthroplastyThe Bone & Joint Journal, 2015
- Tibial Loading After UKA: Evaluation of Tibial Slope, Resection Depth, Medial Shift and Component RotationThe Journal of Arthroplasty, 2013
- Changes in the Medial and Lateral Posterior Condylar Offset in Total Knee ArthroplastyThe Journal of Arthroplasty, 2011