Intermonitor Reliability of the SENS Accelerometer When Worn on the Thigh, Hip, and Wrists in a Laboratory Setting
- 1 January 2025
- journal article
- Published by Human Kinetics in Journal for the Measurement of Physical Behaviour
- Vol. 8 (1)
Abstract
Purpose : Our study evaluated the intermonitor reliability of the SENS accelerometer for raw acceleration, counts, steps, physical activity intensity, and physical activity types/postures in a laboratory setting. Methods: A total of 61 apparently healthy adults (54% female, 21.6 ± 4.2 years) completed ∼10 activities of daily living in a single laboratory visit while wearing two SENS devices side-by-side at one or more of the following body locations: right anterior thigh, right hip, nondominant wrist, and dominant wrist. Outcomes (raw acceleration, counts, steps, and activity intensity for all locations, plus activity types/postures for thigh location) were compared between two devices placed at the same body location using correlations, kappa, percent agreement, and linear mixed models. Results: Strong agreement was found between side-by-side devices worn at the thigh and dominant wrist and, to a lesser extent, the nondominant wrist and hip for mean acceleration ( r = .80–.97), counts ( r = .94–1.00), total steps ( r = .88–.94 for thigh, r = .58–.92 for wrists, and r = .17–.39 for hip), and activity intensity (κ = .92–.95 for thigh, κ = .74–.75 for dominant wrist, κ = .47–.57 for nondominant wrist, and κ = .48–.58 for hip) and activity type/posture for the thigh ( r = .75–.94). Time spent in sedentary, light, and moderate- to vigorous-intensity physical activity was not significantly different between devices for any tested placement. Conclusion: The SENS device, especially when thigh-worn, has strong intermonitor reliability for several physical activity outcomes and appears suitably reliable for use in apparently healthy adults.Keywords
This publication has 23 references indexed in Scilit:
- The patient’s perspective on rehabilitation with wireless accelerometers, activity tracking and motivational feedback following knee replacement: A qualitative study prior to a randomised controlled trial (KneeActivity)International Journal of Medical Informatics, 2024
- A Consensus Method for Estimating Moderate to Vigorous Physical Activity Levels in Adults Using Wrist-Worn AccelerometersJournal for the Measurement of Physical Behaviour, 2024
- Validation of an accelerometer system for measuring physical activity and sedentary behavior in healthy children and adolescentsEuropean Journal of Pediatrics, 2023
- A consensus method for estimating physical activity levels in adults using accelerometryJournal of Sports Sciences, 2022
- Comparability of accelerometer signal aggregation metrics across placements and dominant wrist cut points for the assessment of physical activity in adultsScientific Reports, 2019
- The Applicability of Thigh-Worn vs. Hip-Worn ActiGraph Accelerometers During Walking and RunningJournal for the Measurement of Physical Behaviour, 2019
- An Optimised Algorithm for Accurate Steps Counting From Smart-Phone Accelerometry2018
- Robust and Accurate Smartphone-Based Step Counting for Indoor LocalizationIEEE Sensors Journal, 2017
- Accelerometer Data Collection and Processing Criteria to Assess Physical Activity and Other Outcomes: A Systematic Review and Practical ConsiderationsSports Medicine, 2017
- Edinburgh Handedness Inventory – Short Form: A revised version based on confirmatory factor analysisLaterality, 2013