Abstract
Earables are now pervasive, and their established purpose, ergonomy, and noninvasive interaction uncover exciting opportunities for sensing and healthcare research. However, it is critical to understand and characterize sensory measurements’ accuracy in earables impacting healthcare decisions. We report a systematic characterization of in-ear photoplethysmography (PPG) in measuring vital signs: heart rate (HR), heart rate variability (HRV), blood oxygen saturation (SpO $_2$ ), and respiration rate (RR). We explore in-ear PPG inaccuracies stemming from different sensor placements and motion-induced artifacts. We observe statistically significant differences across sensor placements and between artifact types, with ITC placement showing the lowest intersubject variability. However, our study shows the absolute error climbs up to 29.84, 24.09, 3.28, and 30.80%, respectively, for HR, HRV, SpO $_2$ , and RR during motion activities. Our preliminary results suggest that in-ear PPG is reasonably accurate in detecting vital signs but demands careful mechanical design and signal processing treatment.
Keywords
This publication has 16 references indexed in Scilit:
- The physiological effects of slow breathing in the healthy humanBreathe, 2017
- Photoplethysmography-based in-ear sensor system for identification of increased stress arousal in everyday life2017
- A Lightweight and Inexpensive In-ear Sensing System For Automatic Whole-night Sleep Stage Monitoring2016
- An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogramPhysiological Measurement, 2016
- Earbud-Based Sensor for the Assessment of Energy Expenditure, HR, and V˙O2maxMedicine & Science in Sports & Exercise, 2014
- Evaluating Innovative In-Ear Pulse Oximetry for Unobtrusive Cardiovascular and Pulmonary Monitoring During SleepIEEE Journal of Translational Engineering in Health and Medicine, 2013
- Anatomy of the External Ear2013
- Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteersPhysiological Measurement, 2012
- Relations between ac-dc components and optical path length in photoplethysmographyJournal of Biomedical Optics, 2011
- A Flexible, Low Noise Reflective PPG Sensor Platform for Ear-Worn Heart Rate Monitoring2009