Accuracy of a Digital Impression System Based on Active Triangulation Technology With Blue Light for Implants
- 1 October 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 24 (5) , 498-504
Abstract
Purpose: To evaluate the accuracy of a digital impression system considering clinical parameters. Materials and Methods: A master model with 6 implants (27, 25, 22, 12, 15, and 17) was fitted with polyether ether ketone scan bodies. Implant no. 25 was placed with 30° mesial angulation and no. 15 with 30° distal angulation in relation to the vertical plane (y axis). Implant no. 22 was placed at 2 mm and no. 12 placed 4 mm below the gingiva. Experienced (n = 2) and inexperienced (n = 2) operators performed the scanning (CEREC system). Measurements involved 5 distances (27–25, 27–22, 27–12, 27–15, 27–17). Measurements with coordinated measuring machine of the master model acted as the true values. Results: The experience of the operator affected the accuracy. Operator 3 (inexperienced) performed better than the rest. Angulation and implant depth did not affect the accuracy results. The position of the camera affected the accuracy of the system. The first scanned quadrant had significantly smaller error, −17 ± 26.3 μm, than the second quadrant, −116 ± 103 μm. Conclusions: Digital impressions with CEREC Bluecam system can be a feasible alternative for challenging cases where angulation and depth of the implants are present. The accuracy of the CEREC system for the first scanned quadrant is high, and it decreases when completing a full arch.Keywords
This publication has 16 references indexed in Scilit:
- A Clinical Protocol for Intraoral Digital Impression of Screw-Retained CAD/CAM Framework on Multiple Implants Based on Wavefront Sampling TechnologyImplant Dentistry, 2013
- Accuracy of a Digital Impression System Based on Active Wavefront Sampling Technology for Implants Considering Operator Experience, Implant Angulation, and DepthClinical Implant Dentistry and Related Research, 2013
- Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniquesClinical Oral Investigations, 2013
- Accuracy of Dies Captured by an Intraoral Digital Impression System Using Parallel Confocal ImagingThe International Journal of Prosthodontics, 2013
- The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systemsClinical Oral Investigations, 2013
- Accuracy of digital and conventional impression techniques and workflowClinical Oral Investigations, 2012
- Accuracy of digital models obtained by direct and indirect data capturingClinical Oral Investigations, 2012
- The future of dental devices is digitalDental Materials, 2012
- Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront samplingJournal of Dentistry, 2010
- Computer‐assisted implantology: historical background and potential outcomes—a reviewThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008