The extended wedge method: Atomic force microscope friction calibration for improved tolerance to instrument misalignments, tip offset, and blunt probes
- 1 May 2013
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (5) , 055108
Abstract
One of the major challenges in understanding and controlling friction is the difficulty in bridging the length and time scales of macroscale contacts and those of the single asperity interactions they comprise. While the atomic force microscope (AFM) offers a unique ability to probe tribological surfaces in a wear-free single-asperity contact, instrument calibration challenges have limited the usefulness of this technique for quantitative nanotribological studies. A number of lateral force calibration techniques have been proposed and used, but none has gained universal acceptance due to practical considerations, configuration limitations, or sensitivities to unknowable error sources. This paper describes a simple extension of the classic wedge method of AFM lateral force calibration which: (1) allows simultaneous calibration and measurement on any substrate, thus eliminating prior tip damage and confounding effects of instrument setup adjustments; (2) is insensitive to adhesion, PSD cross-talk, transducer/piezo-tube axis misalignment, and shear-center offset; (3) is applicable to integrated tips and colloidal probes; and (4) is generally applicable to any reciprocating friction coefficient measurement. The method was applied to AFM measurements of polished carbon (99.999% graphite) and single crystal MoS2 to demonstrate the technique. Carbon and single crystal MoS2 had friction coefficients of μ = 0.20 ± 0.04 and μ = 0.006 ± 0.001, respectively, against an integrated Si probe. Against a glass colloidal sphere, MoS2 had a friction coefficient of μ = 0.005 ± 0.001. Generally, the measurement uncertainties ranged from 10%–20% and were driven by the effect of actual frictional variation on the calibration rather than calibration error itself (i.e., due to misalignment, tip-offset, or probe radius).Keywords
This publication has 23 references indexed in Scilit:
- Force calibration in lateral force microscopy: a review of the experimental methodsJournal of Physics D: Applied Physics, 2010
- Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensorReview of Scientific Instruments, 2008
- Effect of contact stiffness on wedge calibration of lateral force in atomic force microscopyReview of Scientific Instruments, 2007
- Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring systemReview of Scientific Instruments, 2006
- Quantitative Nanotribology by AFM: A Novel Universal Calibration PlatformLangmuir, 2006
- An improved wedge calibration method for lateral force in atomic force microscopyReview of Scientific Instruments, 2003
- Quantitative comparison of three calibration techniques for the lateral force microscopeReview of Scientific Instruments, 2001
- Calibration of the torsional spring constant and the lateral photodiode response of frictional force microscopesReview of Scientific Instruments, 2000
- Scanning force microscopy—calibrative procedures for ‘best practice’Scanning, 1997
- Calibration of frictional forces in atomic force microscopyReview of Scientific Instruments, 1996