Prediction of pre‐eclampsia using maternal hemodynamic parameters at 12 + 0 to 15 + 6 weeks
Open Access
- 18 January 2025
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 65 (2) , 173-182
Abstract
Objectives: To compare the maternal hemodynamic profile at 12 + 0 to 15 + 6 weeks' gestation in women who subsequently developed pre‐eclampsia (PE) and those who did not, and to assess the screening performance of maternal hemodynamic parameters for PE in combination with the Fetal Medicine Foundation (FMF) triple test, including maternal factors (MF), mean arterial pressure (MAP), uterine artery pulsatility index and placental growth factor.Methods: This was a prospective case–control study involving Chinese women with a singleton pregnancy who underwent preterm PE screening at 11 + 0 to 13 + 6 weeks' gestation using the FMF triple test, between February 2020 and February 2023. Women identified as being at high risk (≥ 1:100) for preterm PE by the FMF triple test were matched 1:1 with women identified as low risk (< 1:100) for maternal age ± 3 years, maternal weight ± 5 kg and date of screening ± 14 days. Two‐dimensional transthoracic echocardiography was performed at 12 + 0 to 15 + 6 weeks to evaluate maternal hemodynamic parameters (heart rate (HR), stroke volume (SV), cardiac output (CO) and systemic vascular resistance (SVR)). Maternal hemodynamic parameters were expressed as multiples of the median (MoM) values, determined by linear regression models to adjust for gestational age (GA) and MF. The distribution of log10 MoM values of maternal hemodynamic parameters in cases of PE and unaffected pregnancies, and the association between these hemodynamic parameters and GA at delivery, were assessed. The risks of preterm PE (delivery before 37 weeks) and any‐onset PE (delivery at any time) were reassessed using Bayes' theorem after maternal hemodynamic parameters were added to the FMF triple test. The screening performance for preterm PE and any‐onset PE was determined by the area under the receiver‐operating‐characteristics curve (AUC) and detection rate at a 10% fixed false‐positive rate (FPR). Differences in AUC (ΔAUC) were assessed using DeLong's test.Results: A total of 743 cases were analyzed, of whom 39 (5.2%) subsequently developed PE, including 29 (3.9%) cases of preterm PE and 10 (1.3%) cases of term PE. Mean log10 SVR MoM was significantly higher in cases of preterm PE and any‐onset PE compared with unaffected pregnancies. Mean log10 SV MoM and log10 CO MoM were significantly lower in cases of preterm PE and any‐onset PE compared with unaffected pregnancies. Mean log10 HR MoM was not significantly different between the study groups. Mean log10 CO MoM and log10 SVR MoM were not significantly correlated with GA at delivery in preterm PE and any‐onset PE. For the prediction of preterm PE and any‐onset PE, adding CO or SVR or replacing MAP with CO and SVR in the FMF triple test achieved an identical or greater AUC compared with the FMF triple test, but ΔAUC was not significantly different. In addition, adding CO or SVR or replacing MAP by CO and SVR in the FMF triple test did not improve the detection rate for preterm PE and any‐onset PE at a fixed FPR of 10%.Conclusions: Women with preterm PE or any‐onset PE exhibited increased SVR and decreased CO before the clinical manifestations of PE became apparent. These changes may serve as early indicators of cardiovascular maladaptation. However, assessment of maternal hemodynamics at 12 + 0 to 15 + 6 weeks does not enhance the screening performance for preterm PE and any‐onset PE of these parameters. The FMF triple test remains superior to other biomarker combinations for predicting PE. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.Keywords
This publication has 36 references indexed in Scilit:
- ASPRE trial: risk factors for development of preterm pre‐eclampsia despite aspirin prophylaxisUltrasound in Obstetrics & Gynecology, 2021
- First‐trimester pre‐eclampsia biomarker profiles in Asian population: multicenter cohort studyUltrasound in Obstetrics & Gynecology, 2019
- Screening for pre‐eclampsia by maternal factors and biomarkers at 11–13 weeks' gestationUltrasound in Obstetrics & Gynecology, 2018
- Comparison of diagnostic accuracy of early screening for pre‐eclampsia by NICE guidelines and a method combining maternal factors and biomarkers: results of SPREEUltrasound in Obstetrics & Gynecology, 2018
- Screening for pre‐eclampsia in the first trimester: role of maternal hemodynamics and bioimpedance in non‐obese patientsUltrasound in Obstetrics & Gynecology, 2017
- Multicenter screening for pre‐eclampsia by maternal factors and biomarkers at 11–13 weeks' gestation: comparison with NICE guidelines and ACOG recommendationsUltrasound in Obstetrics & Gynecology, 2017
- Serum placental growth factor in the three trimesters of pregnancy: effects of maternal characteristics and medical historyUltrasound in Obstetrics & Gynecology, 2015
- Medians and correction factors for biochemical and ultrasound markers in Chinese women undergoing first‐trimester screening for trisomy 21Ultrasound in Obstetrics & Gynecology, 2009
- Uterine artery Doppler at 11 + 0 to 13 + 6 weeks and 21 + 0 to 24 + 6 weeks in the prediction of pre‐eclampsiaUltrasound in Obstetrics & Gynecology, 2008
- Early pregnancy changes in hemodynamics and volume homeostasis are consecutive adjustments triggered by a primary fall in systemic vascular toneAmerican Journal of Obstetrics and Gynecology, 1993