Time-resolved measurements with single droplet introduction to investigate space-charge effects in plasma mass spectrometry
Authors:
- 1 February 1999
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 10 (2) , 159-174
Abstract
An investigation of the space-charge induced effects of high concentrations of Pb+ matrix ions on Li+ analyte ions in inductively coupled plasma mass spectrometry (ICP-MS) is presented using a vertically oriented mass spectrometer with single droplet introduction. Greater reproducibility and stability in droplet-to-droplet sample introduction using the monodisperse microparticulate injector (MDMI) was achieved with the vertical orientation. Typical variation (%RSD) in the droplet-to-droplet arrival times, and mass spectrometry peak analytical areas are better than 5%. With this precision, a more quantitative description of the space-charge effect on a single cloud of ions is obtained. Both radial and axial space-charge effects were found to occur in the ion beam. Radial effects result in a loss in intensity because of poor transmission or collisions at surfaces within the mass spectrometer. Axial effects modify the kinetic energy distribution of background ion beam components (e.g., 16O+ and 40Ar+) and sampled ion cloud constituents (e.g., 7Li+). However, axial effects do not appear to generate significant broadening of sampled ion clouds within the mass spectrometer. At the point of charge separation and high ion-beam charge density, the ion cloud maxima for Li and Pb are not coincident. This is because of mass dependent diffusion in the ICP as the ion clouds approach the sampling orifice. Space-charge induced ion loss occurs predominantly at a localized region after the Li+ sampled cloud peak maximum. When the Pb concentration in the sample is sufficiently high the 7Li+ sampled signal has a bimodal peak shape. The existence of the dip and its relative location in the bimodal 7Li+ sampled signal suggests that space-charge effects are localized to the region of high charge density occurring just after charge separation.Keywords
This publication has 27 references indexed in Scilit:
- Ion deposition experiments as a tool for the study of the spatial distribution of analyte ions in the second vacuum stage of an inductively coupled plasma mass spectrometerSpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1996
- Spatially resolved measurements of ion density behind the skimmer of an inductively coupled plasma mass spectrometerSpectrochimica Acta Part B: Atomic Spectroscopy, 1996
- Space‐charge effects and ion distribution in plasma source mass spectrometryJournal of Mass Spectrometry, 1995
- Gas and Ion Dynamics of a Three-Aperture Vacuum Interface for Inductively Coupled Plasma-Mass SpectrometryApplied Spectroscopy, 1994
- Reduction of Space Charge Effects Using a Three-Aperture Gas Dynamic Vacuum Interface for Inductively Coupled Plasma-Mass SpectrometryApplied Spectroscopy, 1994
- Space charge in ICP-MS: calculation and implicationsSpectrochimica Acta Part B: Atomic Spectroscopy, 1992
- Alteration of the ion-optic lens configuration to eliminate mass-dependent matrix-interference effects in inductively coupled plasma-mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- Matrix-effect observations in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1987
- Suppression of analyte signal by various concomitant salts in inductively coupled plasma mass spectrometryAnalytical Chemistry, 1986