Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI
- 11 January 2011
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 41 (6) , 711-720
Abstract
Background Cardiovascular flow is commonly assessed with two-dimensional, phase-contrast MRI (2-D PC-MRI). However, scan prescription and acquisition over multiple planes is lengthy, often requires direct physician oversight and has inconsistent results. Time-resolved volumetric PC-MRI (4-D flow) may address these limitations. Objective We assess the degree of agreement and internal consistency between 2-D and 4-D flow quantification in our clinical population. Materials and methods Software enabling flow calculation from 4-D flow was developed in Java. With IRB approval and HIPAA compliance, 18 consecutive patients without shunts were identified who underwent both (1) conventional 2-D PC-MRI of the aorta and main pulmonary artery and (2) 4-D flow imaging. Aortic and pulmonary flow rates were assessed with both techniques. Results Both methods showed general agreement in flow rates (ρ: 0.87–0.90). Systemic and pulmonary arterial flow rates were well-correlated (ρ: 4-D 0.98–0.99, 2-D 0.93), but more closely matched with 4-D (P < 0.05, Brown-Forsythe). Pulmonary flow rates were lower than systemic rates for 2-D (P < 0.05, two-sample t-test). In a sub-analysis of patients without pulmonary or aortic regurgitation, 2-D showed improved correlation of flow rates while 4-D phase-contrast remained tightly correlated (ρ: 4-D 0.99–1.00, 2-D 0.99). Conclusion 4-D PC-MRI demonstrates greater consistency than conventional 2-D PC-MRI for flow quantification.Keywords
This publication has 25 references indexed in Scilit:
- Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurementsJournal of Cardiovascular Magnetic Resonance, 2010
- Optimized parallel imaging for dynamic PC‐MRI with multidirectional velocity encodingMagnetic Resonance in Medicine, 2010
- Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitionsJournal of Cardiovascular Magnetic Resonance, 2009
- Flow Measurement by Magnetic Resonance: A Unique Asset Worth OptimisingJournal of Cardiovascular Magnetic Resonance, 2007
- Peak Velocity and Flow Quantification Validation for Sensitivity-Encoded Phase-Contrast MR ImagingAcademic Radiology, 2007
- Time‐resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imagingMagnetic Resonance in Medicine, 2006
- Three-dimensional, isotropic MRI: a unified approach to quantification and visualization in congenital heart diseaseThe International Journal of Cardiovascular Imaging, 2005
- Cardiovascular applications of magnetic resonance flow and velocity measurementsJournal of Magnetic Resonance Imaging, 1996
- Semiautomated method for noise reduction and background phase error correction in MR phase velocity dataJournal of Magnetic Resonance Imaging, 1993
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991