Complete Electrolysis Using a Microflow Cell with an Oil/Water Interface
- 15 January 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (5) , 1177-1181
Abstract
A novel microflow cell with a nitrobenzene (NB)/water (W) interface was developed. A poly(tetrafluoroethylene) membrane filter was employed to prepare the NB/W interface which was formed over a thin channel (0.1 mm thick, 48 cm long) on a silver plate. The silver plate was electrolyzed in advance and served as an Ag/AgCl electrode for controlling the Galvani potential difference across the NB/W interface as well as detecting the current flowing through the interface. Using the microflow cell, complete electrolysis was accomplished for the interfacial transfer of a representative ion (i.e., tetramethylammonium ion). Thus, the present microflow cell was shown to be promising for coulometric (i.e., absolute quantitative) analysis of ions. Also, the microflow cell was shown to be useful for determination of the number of electrons for complicated charge-transfer processes at the oil/water interface.Keywords
This publication has 19 references indexed in Scilit:
- Mechanistic aspects associated with the oxidation of l-ascorbic acid at the 1,2-dichloroethane∣water interfaceJournal of Electroanalytical Chemistry, 2001
- Application of the flow‐through analyses of ammonia and calcium in ice core and fresh water by fluorometric detectionField Analytical Chemistry & Technology, 2001
- Pulse Amperometric Detection of Lithium in Artificial Serum Using a Flow Injection System with a Liquid/Liquid-Type Ion-Selective ElectrodeAnalytical Chemistry, 1998
- Reduction of flavin mononucleotide at the aqueous/organic solution interface in the absence and presence of oxygenJournal of Electroanalytical Chemistry, 1997
- Oxidation of ascorbate and ascorbic acid at the aqueous|organic solution interfaceJournal of Electroanalytical Chemistry, 1997
- Simultaneous determination of nitrate and chloride by means of flow-injection amperometry at the membrane-stabilized water/nitrobenzene interfaceAnalytica Chimica Acta, 1992
- Voltammetric study of the transfer of Dawson-type heteropolyanions across the nitrobenzene—water interfaceJournal of Electroanalytical Chemistry, 1992
- EditorialElectroanalysis, 1989
- A.c. Polarographic Study of Ion Transfer at the Water/Nitrobenzene InterfaceBulletin of the Chemical Society of Japan, 1984
- Electrolytic Chromatography and Coulopotentiography - A Rapid Electrolysis at the Column Electrode Used for the Preparation, Separation, Concentration, and Estimation of Trace and/or Unstable SubstancesCritical Reviews in Analytical Chemistry, 1977