Comparison of Voltammetric Techniques for Ammonia Sensing in Ionic Liquids
- 7 November 2017
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 30 (1) , 75-83
Abstract
In electroanalytical chemistry, it is often observed that square wave voltammetry (SWV) and differential pulse voltammetry (DPV) are more sensitive techniques compared to linear sweep voltammetry (LSV), due to their method of sampling which minimises the charging current (non‐faradaic processes). In this work, a comparison of the three techniques (LSV, DPV and SWV) is performed for ammonia (NH3) gas oxidation (a chemically and electrochemically irreversible redox process) in an ionic liquid over a concentration range of 10–100 ppm. Four different platinum electrodes are employed: a screen‐printed electrode (SPE), a thin‐film electrode (TFE), a microarray thin‐film electrode (MATFE) and a Pt microdisk electrode (μ‐disk). Calibration plots (current vs concentration) for all three different electrochemical techniques on all four surfaces showed excellent linearity with increased concentrations of NH3 gas and relatively low limits of detection (LODs). On the larger mm‐sized surfaces (SPE and TFE), the current responses for LSV and SWV were quite similar, but DPV gave the lowest currents. Whereas for the smaller micron sized electrodes (MATFE and μ‐disk), currents were of the order LSV>SWV>DPV, with LSV being far superior to the pulse techniques. These findings suggest that the pulse techniques of SWV and DPV may not be the optimum methods, particularly on microelectrodes, for the detection of analytes such as ammonia in RTILs.Keywords
Funding Information
- Australian Research Council (DECRA: DE120101456)
This publication has 43 references indexed in Scilit:
- Dynamics of Redox Processes in Ionic Liquids and Their Interplay for Discriminative Electrochemical SensingAnalytical Chemistry, 2012
- Ultraslow Response of Interfacial Tension to the Change in the Phase-Boundary Potential at the Interface between Water and a Room-Temperature Ionic Liquid, Trioctylmethylammonium bis(nonafluorobutanesulfonyl)amideThe Journal of Physical Chemistry B, 2009
- Mechanistic Studies of the Electro-oxidation Pathway of Ammonia in Several Room-Temperature Ionic LiquidsThe Journal of Physical Chemistry C, 2007
- Elucidation of the Electrochemical Oxidation Pathway of Ammonia in Dimethylformamide and the Room Temperature Ionic Liquid, 1‐Ethyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imideElectroanalysis, 2004
- Analysis and Speciation of Traces of Arsenic in Environmental, Food and Industrial Samples by Voltammetry: a ReviewElectroanalysis, 2004
- Electronic tongues for environmental monitoring based on sensor arrays and pattern recognition: a reviewAnalytica Chimica Acta, 2001
- Water-induced accelerated ion diffusion: voltammetric studies in 1-methyl-3-[2,6-(S)-dimethylocten-2-yl]imidazolium tetrafluoroborate, 1-butyl-3-methylimidazolium tetrafluoroborate and hexafluorophosphate ionic liquidsNew Journal of Chemistry, 2000
- Electrochemical oxidation of ammonia in alkaline solutions: its application to an amperometric sensorElectrochimica Acta, 1998
- Electrochemical methods for food and drink analysisElectroanalysis, 1992
- Health effects of exposure to ammonia: Scant informationAmerican Journal of Industrial Medicine, 1990