Machine learning for the early prediction of infants with electrographic seizures in neonatal hypoxic‐ischemic encephalopathy

Authors:

Abstract
Objective: To assess if early clinical and electroencephalography (EEG) features predict later seizure development in infants with hypoxic‐ischemic encephalopathy (HIE).Methods: Clinical and EEG parameters p‐value .037). The clinical and quantitative‐EEG model significantly outperformed the clinical model (MCC 0.513 vs 0.368, p‐value .012). The clinical and quantitative‐EEG model for infants without ASM (n = 131) had MCC 0.588, AUC 0.832. Performance for quantitative aEEG (n = 159) was MCC 0.381, AUC 0.696 and clinical and quantitative aEEG was MCC 0.384, AUC 0.720.Significance: Early EEG background analysis combined with readily available clinical data helped predict infants who were at highest risk of seizures, hours before they occur. Automated quantitative‐EEG analysis was as good as expert analysis for predicting seizures, supporting the use of automated assessment tools for early evaluation of HIE.
Funding Information
  • Health Research Board (NEPTuNE CDA‐2018‐008)
  • Wellcome Trust (098983, 209325)

This publication has 50 references indexed in Scilit: