Comparison of Two Generations of ActiGraph Accelerometers: The CARDIA Study
- 1 June 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 50 (6) , 1333-1340
Abstract
Purpose: This study aimed to examine the comparability of the ActiGraph 7164 and wGT3X-BT wear time, count-based estimates, and average time per day in physical activity of different intensities. Methods: We studied 87 Coronary Artery Risk Development in Young Adults (CARDIA) participants 48–60 yr of age who simultaneously wore the 7164 and wGT3X-BT accelerometers at the waist in 2015–2016, with wear time of ≥4 of 7 d, ≥10 h·d−1 for both monitors. Freedson cutpoints (counts per minute) were used to define sedentary (P = 0.72). The wGT3X-BT values were calibrated to the 7164 values by dividing counts by 1.088. After calibration, no differences were observed between the 7164 and the wGT3X-BT in total counts per day (310,184 ± 129,189 vs 307,085 ± 135,362, P = 0.48), average counts per min per day (349.5 ± 139.5 vs 346.5 ± 147.2, P = 0.54), sedentary (513.2 ± 93.6 vs 509.6 ± 98.6, P = 0.23), light (335.3 ± 81.5 vs 338.7 ± 81.1, P = 0.22), moderate (31.0 ± 21.9 vs 30.3 ± 23.4, P = 0.31), or moderate-to-vigorous minutes per day (33.1 ± 24.6 vs 32.0 ± 26.0, P = 0.13). A significant difference was observed for vigorous minutes per day (0.2 ± 1.0 vs 0.0 ± 0.3, P < 0.01); however, the absolute difference was marginal. Intraclass correlation coefficients showed excellent agreement for all measures (0.95–0.99). Conclusions: After applying a calibration formula, the 7164 and wGT3X-BT were comparable for total wear time, count-based estimates, and average minutes per day in sedentary, light, moderate, and moderate-to-vigorous activity. Findings illustrate a novel methodological approach to facilitate accelerometer data harmonization.Keywords
This publication has 14 references indexed in Scilit:
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Comparison of ActiGraph activity monitors in persons with multiple sclerosis and controlsDisability and Rehabilitation, 2012
- ActiGraph and Actical Physical Activity MonitorsMedicine & Science in Sports & Exercise, 2012
- Mechanical and free living comparisons of four generations of the Actigraph activity monitorInternational Journal of Behavioral Nutrition and Physical Activity, 2012
- Unit-specific calibration of Actigraph accelerometers in a mechanical setup – Is it worth the effort? The effect on random output variation caused by technical inter-instrument variability in the laboratory and in the fieldBMC Medical Research Methodology, 2008
- Physical Activity in the United States Measured by AccelerometerMedicine & Science in Sports & Exercise, 2008
- Calibration of Accelerometer Output for AdultsMedicine & Science in Sports & Exercise, 2005
- Calibration of the Computer Science and Applications, Inc. accelerometerMedicine & Science in Sports & Exercise, 1998
- Racial differences in serum cotinine levels among smokers in the Coronary Artery Risk Development in (Young) Adults study.American Journal of Public Health, 1990
- Cardia: study design, recruitment, and some characteristics of the examined subjectsJournal of Clinical Epidemiology, 1988