Reducing contamination parameters for clumped isotope analysis: The effect of lowering Porapak™ Q trap temperature to below –50°C
Open Access
- 10 July 2017
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (16) , 1313-1323
Abstract
Rationale: Carbonate clumped isotope thermometry examines the thermodynamic preference of 13 C– 18 O bonds to form within the carbonate crystal lattice. The 13 C 18 O 16 O isotopologue in analyte CO 2 has a natural abundance of 44.4 ppm necessitating stringent purification procedures to remove contaminant molecules that may produce significant isobaric effects within range of the mass 47 isotopologue. Strict purifications of analyte CO 2 are thus required as well as reliable contamination indicators. Methods: CO 2 purification was carried out by vacuum cryogenic purification through a static trap packed with Porapak™ Q (PPQ). The correlation between mass excesses on m/z 47, 48 and 49 in CO 2 produced by acid digestion of 12 natural samples was measured by isotope ratio mass spectrometry (IRMS). CO 2 from two contaminated carbonate samples was then purified at PPQ trap temperatures between –25 and –65°C and measured by IRMS to determine changes in mass excesses on m/z 47, 48 and 49. Finally carbonate standards, Carrara marble (CM) and ETH3, were purified at PPQ trap temperatures of –35 and –60°C to identify isotopic fractionation associated with lowering trap temperature. Results: The correlation between mass excesses on m/z 47, 48 and 49 is determined to be sample dependent. Lowering the PPQ trap temperature to –60°C has a 78% success rate in decreasing Δ 48offset , a measure of sample contamination, to within an acceptable range (13 C and δ 18 O values as a result of isotopic fractionation . We demonstrate that we can correct for fractionation at a trap temperature of –60°C. Conclusions: Lowering the temperature of the Porapak Q trap to –60°C results in improved sample cleaning. It is possible to correct for fractionation in δ 13 C and δ 18 O values at lower PPQ trap temperatures using identically prepared standards. This result has important connotations for laboratories using similar sample preparation methods.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/M506345/1)
This publication has 34 references indexed in Scilit:
- Carbonates in the Martian meteorite Allan Hills 84001 formed at 18 ± 4 °C in a near-surface aqueous environmentProceedings of the National Academy of Sciences, 2011
- 13C–18O isotope signatures and ‘clumped isotope’ thermometry in foraminifera and coccolithsGeochimica et Cosmochimica Acta, 2010
- Body temperatures of modern and extinct vertebrates from 13 C- 18 O bond abundances in bioapatiteProceedings of the National Academy of Sciences, 2010
- Methods and limitations of ‘clumped’ CO2 isotope (Δ47) analysis by gas‐source isotope ratio mass spectrometryJournal of Mass Spectrometry, 2009
- Temperatures of aqueous alteration and evidence for methane generation on the parent bodies of the CM chondritesGeochimica et Cosmochimica Acta, 2007
- “Clumped-isotope” geochemistry—The study of naturally-occurring, multiply-substituted isotopologuesEarth and Planetary Science Letters, 2007
- Preferential formation of 13C–18O bonds in carbonate minerals, estimated using first-principles lattice dynamicsGeochimica et Cosmochimica Acta, 2006
- 13C–18O bonds in carbonate minerals: A new kind of paleothermometerGeochimica et Cosmochimica Acta, 2006
- Abundance of mass 47 CO2 in urban air, car exhaust, and human breathGeochimica et Cosmochimica Acta, 2006
- 18O13C16O in Earth’s atmosphereGeochimica et Cosmochimica Acta, 2004