Firesafety Analysis of the Polar Icebreaker Replacement Design

Authors:
  • RFR.W. Fitzgerald
    R.W. Fitzgerald
  • RRR.C. Richards
    R.C. Richards
  • CBC.L. Beyler
    C.L. Beyler

Abstract
Fire safety aboard Coast Guard cutters is an important part of their design. In 1987, a pro ject was completed that involved a developmental application of the Ship Fire Safety Engineering Methodology (SFSEM) to the firesafety analysis of the Polar Icebreaker Replacement (PIR) design. The passive and active fire protection was analyzed for every compartment on the PIR in the integrated framework provided by SFSEM. Conventional fire protection engineering was used whenever information necessary for SFSEM was not avail able. Recommendations for alternative solutions to accomplish performance-based fire safety objectives, as well as guidelines for selected fire protection systems on the PIR, were provided.