Application of X-ray Photoelectron Spectroscopy (XPS) for the Surface Characterization of Gunshot Residue (GSR)
- 28 February 2011
- journal article
- surface analysis
- Published by Oxford University Press (OUP) in Microscopy Today
- Vol. 19 (2) , 40-45
Abstract
Gunshot residue (GSR) is typically found on the hands or clothing of persons who have been in the environment of a discharging firearm, but it may also be found on objects in the vicinity of the discharge. Computer-controlled scanning electron microscopy (CCSEM) is the method preferred by the forensic community for the automated analysis of GSR. GSR samples are therefore typically collected from a crime suspect's hands and/or clothing using SEM sample stubs coated with a conductive adhesive. The three major components in modern firearm cartridge primers are lead styphanate (initiator), antimony sulfide (fuel), and barium nitrate (oxidizer). GSR consists of the products of combustion of these primer materials. Large populations of particles in the size range of ~1–10 μm are rapidly screened by energy-dispersive X-ray spectroscopy (EDS) for the presence of combinations of Pb, Sb, and Ba. When combinations of these three elements are detected, the particles are flagged as potential GSR particulate. Flagged particles with significant Pb/Sb/Ba compositions are subsequently relocated for a live identification and a positive confirmation of GSR. Positive particles are classified as being either “characteristic of GSR” (that is, all three key elements are present) or “consistent with GSR” (that is, any two of the key elements are present) based on the particle composition and morphology. Classification is based on the presence of the constituent elements and is not dependant on the element amounts. If a particle does not meet the proper compositional or morphological criteria, it is rejected as GSR. However, CCSEM generally does not provide information regarding the population of particles much less than 1 μm or the surface chemistry of the GSR particles. This article examines the fine fraction of GSR particles with high-resolution electron microscopy and complements the microscopy data with surface chemistry information from X-ray photoelectron spectroscopy (XPS).Keywords
This publication has 10 references indexed in Scilit:
- XPS analysis of nanostructured materials and biological surfacesJournal of Electron Spectroscopy and Related Phenomena, 2010
- The potential for the application of X‐ray photoelectron spectroscopy in forensic scienceSurface and Interface Analysis, 2010
- Application of surface chemical analysis tools for characterization of nanoparticlesAnalytical and Bioanalytical Chemistry, 2010
- An Introduction to Surface Analysis by XPS and AES2003
- Microchemical and micromorphological features of gunshot residue observed by combined use of AFM, SA‐XPS and SEM + EDSSurface and Interface Analysis, 2002
- Characterisation of 0.22 caliber rimfire gunshot residues by time-of-flight secondary ion mass spectrometry (TOF-SIMS): a preliminary studyForensic Science International, 2001
- Current Methods in Forensic Gunshot Residue Analysis2000
- Survey of Gunshot Residue Analysis in Forensic Science LaboratoriesJournal of Forensic Sciences, 1990
- Automation of Gunshot Residue Detection and Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Analysis (SEM/EDX)Journal of Forensic Sciences, 1987
- Automated Gunshot Residue Particle Search and CharacterizationJournal of Forensic Sciences, 1987