Kinetic models for PET displacement studies
Authors:
- Gjertrud Louise LaurellGLGjertrud Louise Laurell
- Pontus Plavén-SigrayPPPontus Plavén-Sigray
- Annette JohansenAJAnnette Johansen
- Nakul Ravi RavalNakul Ravi Raval
- Arafat NasserANArafat Nasser
- Clara Aabye MadsenCMClara Aabye Madsen
- Jacob MadsenJMJacob Madsen
- Hanne Demant HansenHHHanne Demant Hansen
- Gitte Moos KnudsenGKGitte Moos Knudsen
- Adriaan A LammertsmaALAdriaan A Lammertsma
Preprint
Abstract
The traditional design of PET target engagement studies is based on a baseline scan and one or more scans after drug administration. We here evaluate an alternative design in which the drug is administered during an on-going scan (i.e., a displacement study). This approach results both in lower radiation exposure and lower costs. Existing kinetic models assume steady state. This condition is not present during a drug displacement and consequently, our aim here was to develop kinetic models for analysing PET displacement data. We modified existing compartment models to accommodate a time-variant increase in occupancy following the pharmacological in-scan intervention. Since this implies the use of differential equations that cannot be solved analytically, we developed instead one approximate and one numerical solution. Through simulations, we show that if the occupancy is relatively high, it can be estimated without bias and with good accuracy. The models were applied to PET data from six pigs where [ 11 C]UCB-J was displaced by intravenous brivaracetam. The dose-occupancy relationship estimated from these scans showed good agreement with occupancies calculated with Lassen plot applied to baseline-block scans of two pigs. In summary, the proposed models provide a framework to determine target occupancy from a single displacement scan.Keywords
This publication has 41 references indexed in Scilit:
- A restricted access material for rapid analysis of [11C]-labeled radiopharmaceuticals and their metabolites in plasmaNuclear Medicine and Biology, 2009
- Measuring Drug Occupancy in the Absence of a Reference Region: The Lassen Plot Re-VisitedJournal of Cerebral Blood Flow & Metabolism, 2009
- Impact of Image-Space Resolution Modeling for Studies with the High-Resolution Research TomographJournal of Nuclear Medicine, 2008
- Consensus Nomenclature for in vivo Imaging of Reversibly Binding RadioligandsJournal of Cerebral Blood Flow & Metabolism, 2007
- An extended simplified reference tissue model for the quantification of dynamic PET with amphetamine challengeNeuroImage, 2006
- Modified Regression Model for the Logan PlotJournal of Cerebral Blood Flow & Metabolism, 2002
- Assessment of Dynamic Neurotransmitter Changes with Bolus or Infusion Delivery of Neuroreceptor LigandsJournal of Cerebral Blood Flow & Metabolism, 1998
- Kinetic Modeling of [11C]Raclopride: Combined PET-Microdialysis StudiesJournal of Cerebral Blood Flow & Metabolism, 1997
- Simplified Reference Tissue Model for PET Receptor StudiesNeuroImage, 1996
- Benzodiazepine Receptor Quantification in vivo in Humans Using [11C]Flumazenil and PET: Application of the Steady-State PrincipleJournal of Cerebral Blood Flow & Metabolism, 1995