Management of the unexplained, painful large diameter metal-on-metal (MOM) hip replacement is difficult. Although there are guidelines for surgeons, there is no clear documented evidence describing the overall threshold for revision surgery. The 2010 product recall of the DePuy Articular Surface Replacement (ASR) and subsequent media coverage may have increased patient and surgeon apprehension, resulting in earlier intervention, i.e. at a greater Oxford hip score (OHS) than expected. Our aim was to investigate whether the threshold for revision using known parameters was affected by the ASR recall. These parameters include poor clinical results (persistent pain or mechanical symptoms), pseudotumour or other progressive soft tissue involvement, osteolysis and high or rising metal ion levels. We used our national referral database of MOM hips, which were revised between 2008 and 2012. Once inclusion and exclusion criteria were applied, we identified 240 patients—71 patients in the pre-recall group and 169 patients in the post-recall group. The ASR product recall did not seem to affect the threshold for revision of a MOM hip, with no significant difference between the two groups in terms of the functional (median OHS = 17 pre-recall and 20 post-recall; p = 0.2109) and radiological (median inclination angle = 50 pre-recall and 48 post-recall; p = 0.3221) markers used to guide management. We did however discover that blood metal ion levels were higher in the post-recall group. Issue of a product recall did not change the hip function threshold for revision surgery. The decision to revise a metal-on-metal hip is complex and should follow published guidelines, encompassing metal ion measurement and cross-sectional imaging where appropriate.Keywords
This publication has 11 references indexed in Scilit:
- The 2012 Otto Aufranc Award: The Interpretation of Metal Ion Levels in Unilateral and Bilateral Hip ResurfacingClinical Orthopaedics and Related Research, 2013
- Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplastyInternational Orthopaedics, 2012
- Hip resurfacing in patients under thirty years old: an attractive option for young and active patientsInternational Orthopaedics, 2012
- Metal-on-metal failures—in science, regulation, and policyThe Lancet, 2012
- Perspectives in Managing an Implant Recall: Revision of 94 Durom Metasul Acetabular ComponentsJournal of Bone and Joint Surgery, 2011
- Metal-on-metal bearingsThe Journal of Bone and Joint Surgery. British volume, 2011
- Revision Arthroscopic Contracture Release in the Elbow Resulting in an Ulnar Nerve TransectionJournal of Bone and Joint Surgery, 2011
- Hip resurfacings revised for inflammatory pseudotumour have a poor outcomeThe Journal of Bone and Joint Surgery. British volume, 2009
- Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopeniaThe Journal of Bone and Joint Surgery. British volume, 2009
- Lessons of a hip failureBMJ, 1998