Abstract
Standard pullout tests (e.g., 150 mm cubes) with a short embedment length have shown a significant reduction (80% loss at 200°C) in the bond strength of glass fiber-reinforced polymer (GFRP) bars at high temperatures but little information is known about how this information can be extended to longer embedment lengths. To address this knowledge gap, a more detailed bond behavior of GFRP reinforcing bars has been examined in this study with a modified pullout test method in which pullout specimens consisting of GFRP bars embedded in 350 mm (22db) long concrete cylinders were tested at high temperatures. The tests examined the bond degradation under different temperature distributions (i.e., uniform and gradient). The results were compared with the previous pullout tests with 68 mm (4db) embedment length and showed that the pullout capacity of GFRP bars in this test was 3.3, 4.0, and 2.0 times higher at 115°C, 135°C, and 300°C, respectively. The results were the first to prove the effectiveness of longer embedment length particularly at temperatures below 200°C. Additionally, pullout tests with temperature gradients simulated the bond behavior of GFRP bars at the unexposed end zones of GFRP reinforced concrete beams or slabs. The results showed that the tensile force in GFRP bars gradually transferred to the lower temperature zones as the heated parts of the bar lost bond with concrete. The results showed that the concentrated forces over a short length of GFRP bars can trigger concrete splitting and loss of bond even if the GFRP bars still maintain the bond with concrete. Providing thicker concrete cover at the end zones of GFRP reinforced members is recommended to enhance fire resistance. The findings of this study are being used in developing forthcoming FRP reinforced concrete design codes.Keywords
This publication has 26 references indexed in Scilit:
- Bond Durability of FRP Bars Embedded in Fiber-Reinforced ConcreteJournal of Composites for Construction, 2012
- Performance under Fire Situations of Concrete Members Reinforced with FRP Rods: Bond Models and Design NomogramsJournal of Composites for Construction, 2012
- Performance of glass fiber reinforced polymer bars under elevated temperaturesComposites Part B: Engineering, 2012
- Experimental study of bond behaviour between concrete and FRP bars using a pull-out testComposites Part B: Engineering, 2009
- An experimental study of the mechanical properties of fibre reinforced polymer (FRP) and steel reinforcing bars at elevated temperaturesComposite Structures, 2007
- Evaluating the fire endurance of concrete slabs reinforced with FRP bars: Considerations for a holistic approachComposites Part B: Engineering, 2007
- Bond Performances of FRP Rebars-Reinforced ConcreteJournal of Materials in Civil Engineering, 2007
- Response to fire of concrete structures that incorporate FRPProgress in Structural Engineering and Materials, 2005
- Bond Behavior of Fiber Reinforced Polymer Bars under Direct Pullout ConditionsJournal of Composites for Construction, 2004
- Effect of High Temperature on Bond Strength of FRP RebarsJournal of Composites for Construction, 1999