An Algorithm for Predicting the Change in SAR in a Human Phantom Due to Deviations in Its Complex Permittivity
Authors:
- 24 April 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 51 (2) , 217-226
Abstract
The aim of this study is to determine a robust prediction algorithm that can be used to correct the measured specific absorption rate (SAR) in a homogeneous phantom when its complex permittivity deviates from standardized reference values. Results are analyzed over a frequency range of 30-6000 MHz. Both measurements and numerical simulations are presented. Several antenna sizes and distances to the phantom are investigated so as to study a large range of SAR distributions. It is demonstrated that the prediction algorithm, while developed using dipole antennas, also works well for mobile telephone models. Employing the prediction algorithm reduces the SAR measurement uncertainty, thereby improving the reproducibility of SAR compliance assessment between laboratories. Another benefit of the algorithm is that it enables the use of broadband tissue-equivalent liquids, whose dielectric parameters are not currently within the tight tolerances of existing standards. The use of broadband liquids reduces the cost of SAR measurement. The method presented in this paper is of benefit to the IEEE 1528 and IEC 62209 measurement standards.Keywords
This publication has 12 references indexed in Scilit:
- Development and characterisation of tissue equivalent materials for frequency range 30–300 MHzElectronics Letters, 2007
- Complex permittivity of sodium chloride solutions at microwave frequenciesBioelectromagnetics, 2007
- Sensitivity of the spatial-average peak SAR to the dielectric parameters of media used for compliance testing in the frequency range 0.3 - 3 GHz2005
- Influence of Phantom Shell on SAR Measurement in 3-6 GHz Frequency RangeIEICE Transactions on Communications, 2005
- Faster Determination of Mass-Averaged SAR From 2-D Area ScansIEEE Transactions on Microwave Theory and Techniques, 2004
- Formulation and Characterization of Tissue Equivalent Liquids Used for RF Densitometry and Dosimetry MeasurementsIEEE Transactions on Microwave Theory and Techniques, 2004
- The dependence of electromagnetic energy absorption upon human head tissue composition in the frequency range of 300-3000 MHzIEEE Transactions on Microwave Theory and Techniques, 2000
- Radio frequency electromagnetic exposure: Tutorial review on experimental dosimetryBioelectromagnetics, 1996
- A perfectly matched layer for the absorption of electromagnetic wavesJournal of Computational Physics, 1994
- Energy absorption mechanism by biological bodies in the near field of dipole antennas above 300 MHzIEEE Transactions on Vehicular Technology, 1992