The Feasibility of Mri Feedback Control for Intracavitary Phased Array Hyperthermia Treatments
Authors:
Open Access
- 1 January 1998
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 14 (1) , 39-56
Abstract
Temperature feedback control has the potential to enhance hyperthermia treatments by providing more uniform heating of the target volume and improving the transient temperature response. A multivariable least squares batch algorithm was used to estimate system parameters for simulated prostate hyperthermia treatments. A multi-input, multi-output (MIMO) linear quadratic regulator (LQR) controller was designed for prostate hyperthermia treatments with an intracavitary phased array. A parametric study was performed for the one dimensional control case, investigating factors relevant to magnetic resonance imaging (MRI) feedback control such as spatial resolution of temperature measurements (size of the averaging volume), sampling rate (image acquisition time), thermometry noise, control width, control depth, physiological parameter changes and reference input structure. Simulations utilizing the two dimensional (2-D) thermometry of MRI and the 2-D focusing capabilities of phased arrays demonstrated that near field heating can be controlled such that the size and shape of the heated volume can be tailored in 2-D. The control algorithms developed in this study show promising potential for incorporation into a non invasive prostate hyperthermia system utilizing MRI feedback.Keywords
This publication has 18 references indexed in Scilit:
- Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beamMagnetic Resonance in Medicine, 1996
- Intracavitary ultrasound phased arrays for noninvasive prostate surgeryIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1996
- Abdomino-pelvic hypertherma and intraperitoneal carboplatin in epithelial ovarian cancer: Feasibility, tolerance and pharmacologyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Design and optimization of an aperiodic ultrasound phased array for intracavitary prostate thermal therapiesMedical Physics, 1996
- Design and experimental evaluation of an intracavitary ultrasound phased array system for hyperthermiaIEEE Transactions on Biomedical Engineering, 1994
- Feasibility and toxicity of transrectal ultrasound hyperthermia in the treatment of locally advanced adenocarcinoma of the prostateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Acoustic power calibrations of cylindrical intracavitary ultrasound hyperthermia applicatorsMedical Physics, 1993
- Performance of an adaptive MIMO controller for a multiple-element ultrasound hyperthermia systemInternational Journal of Hyperthermia, 1993
- The feasibility of using electrically focused ultrasound arrays to induce deep hyperthermia via body cavitiesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1991
- Multi-point feedback control system for scanned, focused ultrasound hyperthermiaPhysics in Medicine & Biology, 1990