Pollution accumulation on rail insulator in high-speed aerosol
Authors:
- 24 May 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 20 (3) , 731-738
Abstract
Pollution distributes irregularly on the surfaces of traction power supply system insulators as high-speed trains pass through pollution aerosols. This affects the flashover characters. Insulator polluting characteristics were studied in a wind tunnel at speeds up to 100 m/s. The gas-solid aerosol flow around insulator was analyzed and a pollution accumulation model was established after analyzing the forces on dust particles. Additional simulation shows that with the aerosol velocity increases, pollution accumulates more on the windward side and leeside. Accumulation on the leeside increases as the crosswind side decreases. When viscosity and pollution density are constants, the quantity of pollution on upper surface of a post-type third-rail insulator shed is not so uniform, but has maximum and minimum values. This numerical modeling result corresponds well with experiment. A method is proposed to express the pollution distribution using ESDD and NSDD.Keywords
This publication has 12 references indexed in Scilit:
- Flashover process and frequency analysis of the leakage current on insulator model under non-uniform pollution conditionsIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Effect of non-uniform pollution on the withstand characteristics of extra high voltage (EHV) suspension ceramic insulator stringIET Generation, Transmission & Distribution, 2010
- Explosive dissemination and flow of nanoparticlesPowder Technology, 2006
- Experimental and computational study of gas–solid fluidized bed hydrodynamicsChemical Engineering Science, 2005
- Contamination accumulation and withstand voltage characteristics of various types of insulators2004
- Analysis of a frictional–kinetic model for gas–particle flowPowder Technology, 2003
- Long-term tests of HVDC insulators under natural pollution conditions at the Big Eddy Test CenterIEEE Transactions on Power Delivery, 1989
- Effect of interparticle forces on the hydrodynamic behaviour of fluidized aerogelsPowder Technology, 1985
- Performance of HVDC Insulators under Contaminated ConditionsIEEE Transactions on Electrical Insulation, 1980
- Particle Contamination of High Voltage DC Insulators below Corona ThresholdIEEE Transactions on Electrical Insulation, 1979