Step Monitor Accuracy during Poststroke Physical Therapy and Simulated Activities
- 21 December 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Translational Journal of the American College of Sports Medicine
- Vol. 7 (1)
Abstract
Introduction/Purpose: The amount of stepping activity during rehabilitation after stroke can predict walking outcomes, although the most accurate methods to evaluate stepping activity are uncertain with conflicting findings on available stepping monitors during walking assessments. Rehabilitation sessions also include nonstepping activities, and the ability of activity monitors to differentiate these activities from stepping is unclear. The objective of this study was to examine the accuracy of different activity monitors worn by individuals after stroke with variable walking speeds during clinical physical therapy (PT) and research interventions focused on walking. Methods: In part I, 28 participants after stroke wore a StepWatch, ActiGraph with and without a low-frequency extension (LFE) filter, and Fitbit on paretic and nonparetic distal shanks at or above the ankle during clinical PT or research interventions with steps simultaneously hand counted. Mean absolute percent errors were compared between limbs and tasks performed. In part II, 12 healthy adults completed eight walking and nine nonwalking tasks observed during clinical PT or research. Data were descriptively analyzed and used to assist interpretation of part I results. Results: Part I results indicate most devices did not demonstrate an optimal limb configuration during research sessions focused on walking, with larger errors during clinical PT on the nonparetic limb. Using the limb that minimized errors for each device, the StepWatch had smaller errors than the ActiGraph and Fitbit (P < 0.01), particularly in those who walked −1. Conversely, errors from the ActiGraph-LFE demonstrated inconsistent differences in step counts between Fitbit and ActiGraph. Part II results indicate that errors observed during different stepping and nonstepping activities were often device-specific, with nonstepping tasks frequently detected as stepping. Conclusions: The StepWatch and ActiGraph-LFE had smaller errors than the Fitbit or ActiGraph, with greater errors in those walking at slower speeds. Inclusion of nonstepping activities affected step counts and should be considered when measuring stepping activity in individuals after stroke to predict locomotor outcomes after rehabilitation.Keywords
This publication has 44 references indexed in Scilit:
- Comparison of older and newer generations of ActiGraph accelerometers with the normal filter and the low frequency extensionInternational Journal of Behavioral Nutrition and Physical Activity, 2013
- Exercise dose and mobility outcome in a comprehensive stroke unit: Description and prediction from a prospective cohort studyJournal of Rehabilitation Medicine, 2012
- Heart Disease and Stroke Statistics—2011 UpdateCirculation, 2011
- Locomotor Training Improves Daily Stepping Activity and Gait Efficiency in Individuals Poststroke Who Have Reached a “Plateau” in RecoveryStroke, 2010
- Observation of Amounts of Movement Practice Provided During Stroke RehabilitationArchives of Physical Medicine and Rehabilitation, 2009
- Gait Speed and Step-Count Monitor Accuracy in Community-Dwelling Older AdultsMedicine & Science in Sports & Exercise, 2008
- Criterion Validity of the StepWatch Activity Monitor as a Measure of Walking Activity in Patients After StrokeArchives of Physical Medicine and Rehabilitation, 2007
- Comparison of two waist-mounted and two ankle-mounted electronic pedometersEuropean Journal of Applied Physiology, 2005
- Classification of Walking Handicap in the Stroke PopulationStroke, 1995
- Motor Recovery Following Acute StrokeAge and Ageing, 1990