A reversible thermoresponsive sealant for temporary closure of ocular trauma
- 6 December 2017
- journal article
- research article
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 9 (419)
Abstract
Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N-isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat–induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injuries.Keywords
Funding Information
- National Science Foundation (award342979, EEC-0310723)
- National Institutes of Health (award342978, UL1TR000130)
- U.S. Department of War (award342977, W81XWH-12-1-0314)
- U.S. Department of War (award348169, W81XWH-16-C-0086)
- Research to Prevent Blindness (award342980)
This publication has 40 references indexed in Scilit:
- Evaluation of tensile strength of tissue adhesives and sutures for clear corneal incisions using porcine and bovine eyes, with a novel standardized testing platformClinical Ophthalmology, 2012
- Intraocular Pressure Changes: An Important Determinant of the Biocompatibility of Intravitreous ImplantsPLOS ONE, 2011
- Degradation, cytotoxicity, and biocompatibility of NIPAAm‐based thermosensitive, injectable, and bioresorbable polymer hydrogelsJournal of Biomedical Materials Research Part A, 2011
- Mucoadhesive drug delivery systemsJournal of Pharmacy and Bioallied Sciences, 2011
- Stimuli-responsive interfaces and systems for the control of protein–surface and cell–surface interactionsBiomaterials, 2009
- Synthesis and Characterization of Thermo-Sensitive Nanoparticles for Drug Delivery ApplicationsJournal of Biomedical Nanotechnology, 2008
- Improvement of metal and tissue adhesion on surface‐modified parylene CJournal of Biomedical Materials Research Part A, 2008
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- Trends in Eye Injury in the United States, 1992–2001Investigative Ophthalmology & Visual Science, 2006
- Amended Final Report on the Safety Assessment of Polyacrylamide and Acrylamide Residues in Cosmetics1International Journal of Toxicology, 2005