Diffusivity Measurements of Human Methemoglobin
Authors:
Open Access
- 1 March 1966
- journal article
- research article
- Published by Rockefeller University Press in Journal of General Physiology
- Vol. 49 (4) , 681-687
Abstract
Experimental measurements of the diffusion coefficient of human methemoglobin were made at 25 degrees C with a modified Stokes diaphragm diffusion cell. A Millipore filter was used in place of the ordinary fritted disc to facilitate rapid achievement of steady state in the diaphragm. Methemoglobin concentrations varied from approximately 5 g/100 ml to 30 g/100 ml. The diffusion coefficient in this range decreased from 7.5 x 10(-7) cm(2)/sec to 1.6 x 10(-7) cm(2)/sec.Keywords
This publication has 2 references indexed in Scilit:
- The Steady-State Transport of Oxygen through Hemoglobin SolutionsJournal of General Physiology, 1966