Evaluation of corona-resistant magnet wires through partial discharge and space charge measurements
Authors:
- M. ContiMCM. Conti
- D. FabianiD. Fabiani
- G.C. MontanariGMG.C. Montanari
- 13 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 11-16
Abstract
This paper presents the results of space charge and partial discharge measurements carried out on enameled wires, specifically designed to be used in electrical motors fed by adjustable speed drives. These procedures described can provide a useful tool for short-term evaluation of enameled wires, which can give indications also on long-term performance. Partial discharges and space charge accumulation seem to be significantly influenced by the supply voltage waveform features (frequency and shape), with an extent depending on the material itself. Moreover, partial discharge features, such as pulse height and inception voltage, depend considerably on space charge accumulation which may occur, e.g., with unipolar waveforms. Both techniques provide considerably different fingerprints of the two tested kinds of wires.Keywords
This publication has 9 references indexed in Scilit:
- Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse controlled inverters2002
- Stochastic analysis of partial discharges signals for diagnosis of insulation systems of AC rotating machine stator windings2002
- Inverter-Fed Drives: Which Motor Stators Are at Risk?IEEE Industry Applications Magazine, 2000
- Evaluation of dc insulation performance based on space-charge measurements and accelerated life testsIEEE Transactions on Dielectrics and Electrical Insulation, 2000
- Testing of low-voltage motor turn insulation intended for pulse-width modulated applicationsIEEE Transactions on Dielectrics and Electrical Insulation, 2000
- PD source recognition by Weibull processing of pulse height distributionsIEEE Transactions on Dielectrics and Electrical Insulation, 2000
- Acoustic and optical methods for measuring electric charge distributions in dielectricsIEEE Transactions on Dielectrics and Electrical Insulation, 1999
- Failure mechanism of winding insulations in inverter-fed motorsIEEE Electrical Insulation Magazine, 1997
- Existence of partial discharges in low-voltage induction machines supplied by PWM drivesIEEE Transactions on Dielectrics and Electrical Insulation, 1996