Radiation doses in the United Kingdom breast screening programmes 2016–2019
- 1 July 2022
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1135) , 20211400
Abstract
Objectives: To record the radiation doses involved in UK breast screening and to identify any changes since previous publications related to technical factors and the population screened. Methods: Mammographic exposure factors for 68,998 women imaged using 411 X-ray sets spread across the UK were compiled. Local output and half value layer measurements for each X-ray set were used to estimate mean glandular dose (MGD) using the standard UK method. Results: Mean MGDs in digital mammography have increased by 11% since 2010–12 for both medio-lateral oblique (MLO) and cranio-caudal (CC) views. The mean compressed breast thickness (CBT) has increased (4.8% CC, 5.2% MLO) over the same period. The mean MLO CBT value of 62.4 ± 0.1 mm is outside the 50 to 60 mm range used for diagnostic reference levels. The increase in MGD is consistent with the CBT changes. The mean MGD in the 50 to 60 mm CBT range is 1.44 ± 0.03 mGy for MLO views. CBT varies with age and peaks at 51. Conclusions: Mean CBT has increased with time, and this has increased mean MGDs for digital mammography. CBT also varies with age. Advances in knowledge: Updated average MGDs in the UK are provided. There is evidence that breast size is increasing in the UK and that mean CBT is affected by age-related changes in the breast.Keywords
This publication has 21 references indexed in Scilit:
- Breast Cancer Mortality vs. Exercise and Breast Size in Runners and WalkersPLOS ONE, 2013
- The Relationship of Mammographic Density and Age: Implications for Breast Cancer ScreeningAmerican Journal of Roentgenology, 2012
- Clinical dose performance of full field digital mammography in a breast screening programmeBritish Journal of Radiology, 2011
- Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocolsPhysics in Medicine & Biology, 2010
- Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening TrialAmerican Journal of Roentgenology, 2010
- A Survey of Patient Doses from Digital Mammography Systems in the UK in 2007 to 20092010
- Effective dose: how should it be applied to medical exposures?British Journal of Radiology, 2007
- A prospective study of breast size and premenopausal breast cancer incidenceInternational Journal of Cancer, 2005
- Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer ScreeningNew England Journal of Medicine, 2005
- Radiation doses received in the UK Breast Screening Programme in 2001 and 2002British Journal of Radiology, 2005