Two Biosensors for the Determination of VEGF-R2 in Plasma by Array SPRi
Open Access
Abstract
Vascular endothelial growth factor receptor 2 (VEGF-R2) is a marker of angiogenesis and metastasis of cancer. Two biosensors for the determination of VEGF-R2 in plasma have been developed. One of them is based on a pure gold chip, and the other on a silver/gold bimetallic chip; both have the receptor, monoclonal rabbit antibody specific for human VEGF-R2, attached to the chip via a cysteamine linker. The biosensor with the gold chip exhibits linearity of the analytical signal between 0.03 and 2 ng/mL, a precision of 1.4% and recovery between 99% and 102%. The biosensor with the bimetallic chip exhibits linearity between 0.03 and 1 ng/mL, a precision of 2.2% and recovery between 99% and 103%. Both biosensors tolerate a 1:100 excess of VEGF, VEGF-R1 and VEGF-R3. Both biosensors were validated by parallel determination of VEGF-R2 in 27 different plasma samples using the ELISA immunosensor assay, with very good agreement of the results. Thermodynamic parameters of the interaction of VEGF-R2 with the antibody were determined by QCM (Quartz Crystal Microbalance) and SPRi (Surface Plasmon Resonance imaging) measurements.Keywords
Funding Information
- Polish Ministry of Education and Science (BST-162)
- University of Bialystok (BST-162)
This publication has 28 references indexed in Scilit:
- Site-directed antibody immobilization techniques for immunosensorsBiosensors and Bioelectronics, 2013
- Design of a universal biointerface for sensitive, selective, and multiplex detection of biomarkers using surface plasmon resonance imagingThe Analyst, 2013
- Surface plasmon resonance based immunosensor for the detection of the cancer biomarker carcinoembryonic antigenTalanta, 2011
- Plasma concentrations of angiogenetic factors and angiogenetic inhibitors in patients with ductal pancreatic neoplasms. A pilot studyClinical Chemistry and Laboratory Medicine (CCLM), 2011
- Sensitivity Enhancement for Surface Plasmon Resonance Imaging Biosensor by Utilizing Gold–Silver Bimetallic Film ConfigurationPlasmonics, 2011
- Comparison of surface plasmon resonance and capacitive immunosensors for cancer antigen 125 detection in human serum samplesBiosensors and Bioelectronics, 2009
- Label-free detection of cancer biomarker candidates using surface plasmon resonance imagingAnalytical and Bioanalytical Chemistry, 2008
- Detection of Protein Biomarkers Using RNA Aptamer Microarrays and Enzymatically Amplified Surface Plasmon Resonance ImagingAnalytical Chemistry, 2007
- Kinetic analysis of monoclonal antibody-antigen interactions with a new biosensor based analytical systemJournal of Immunological Methods, 1991
- Quantitative determination of surface concentration of protein with surface plasmon resonance using radiolabeled proteinsJournal of Colloid and Interface Science, 1991