The Silk Flow-Diverting Stent in the Endovascular Treatment of Complex Intracranial Aneurysms: Technical Aspects and Midterm Results in 24 Consecutive Patients
- 20 August 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 70 (3) , 617-624
Abstract
Background: The flow-diverting stent is a new option in endovascular therapy specifically designed for the endovascular reconstruction of a segmentally diseased artery. The safety of flow-diverting stents is still equivocal. Objective: To evaluate the technical aspects, thromboembolic events, adjunctive therapies, and midterm results in patients with complex intracranial aneurysms treated with a flow-diverting stent (Silk; Balt Extrusion, Montmorency, France). Methods: We retrospectively examined angiographic images and clinical reports of 24 consecutive patients (29 stents) treated (n = 23) or attempted to treat (n = 1) with a flow-diverting device in 2 Finnish centers between March 2009 and October 2010. Results: The primary technical success rate was 67% (16/24). Adjunctive therapies were required in 6 (25%) patients, including 4 cases where intra-arterial abciximab was administered for the treatment of intraprocedural thromboembolic events. Technique-related complication rate and the 30-day mortality rate were each 4% (1/24). Follow-up imaging revealed 1 case of delayed in-stent thrombosis resulting in permanent disability of the patient, 1 asymptomatic occlusion, and 1 asymptomatic stenosis of the stented artery. Complete occlusion of the aneurysm with fully patent parent artery was observed in 16 of the 23 aneurysms (70%) where follow-up images were available. Conclusion: Many previously untreatable cerebral aneurysms may be successfully treated with the Silk flow-diverting stent, but the associated risk of thromboembolic events is justifiable only if conventional endovascular or surgical treatment options are not applicable. Perioperative thromboembolic events should be prepared for and treated without unnecessary delays because they frequently respond to adjunctive medical therapy.Keywords
This publication has 22 references indexed in Scilit:
- The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms TrialAmerican Journal of Neuroradiology, 2010
- Flow-Diverter Stent for the Endovascular Treatment of Intracranial AneurysmsStroke, 2010
- High-Profile Flow Diverter (Silk) Implantation in the Basilar ArteryStroke, 2010
- Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2010
- Stent-Assisted Coiling of Intracranial AneurysmsStroke, 2010
- Wide-necked Intracranial Aneurysms: Treatment with Stent-assisted Coil Embolization during Acute (<72 Hours) Subarachnoid Hemorrhage—Experience in 61 Consecutive PatientsRadiology, 2009
- Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registryJournal of Neurosurgery, 2009
- Safety and Efficacy of Adjunctive Balloon Remodeling during Endovascular Treatment of Intracranial Aneurysms: A Literature ReviewAmerican Journal of Neuroradiology, 2008
- International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusionThe Lancet, 2005
- Stent-assisted coil embolization of intracranial wide-necked aneurysmsNeuroradiology, 2005