Fracture of the Alumina-bearing Couple Delta Ceramic Liner
Authors:
- Afshin TaheriazamATAfshin Taheriazam
- Mohammad Azizbaig MohajerMMMohammad Azizbaig Mohajer
- Mansoour AboulghasemianMAMansoour Aboulghasemian
- Babak HajipourBHBabak Hajipour
- 1 January 2012
- journal article
- case report
- Published by SLACK, Inc. in Orthopedics
- Vol. 35 (1) , e91-3
Abstract
The fracture rate of third-generation ceramic liners is greatly reduced compared with first- and second-generation liners because of improvements in the design and manufacturing process. Fractures of the alumina-bearing couple are rare for the same reason. This article describes a case of a fracture of an alumina-bearing couple delta ceramic liner without trauma history that was treated with ceramic-on-polyethylene revision total hip arthroplasty. A 57-year-old man was admitted to the hip ward because of an alumina-bearing couple delta ceramic liner fracture. He underwent hip replacement by anterior approach 18 months previously in the same center because of left hip primary osteoarthritis. He received a 54×36-mm modular press-fit cup ceramic alumina-bearing couple delta insert. Probable causes of such fractures are manufacture production failure and edge loading based on cup inclination, but in our patient, inacceptable range of motion, failure of the locking mechanism during implantation insertion, or cracking were possible causes of fracture. Although the fracture rate of third-generation alumina-bearing couples is low, we believe that it may not be possible to eliminate the actual risk of alumina head fracture. Patients should be informed about the potential for this complication before receiving an alumina-bearing couple.Keywords
This publication has 12 references indexed in Scilit:
- Delayed Fracture of a Ceramic Insert With Modern Ceramic Total Hip ReplacementThe Journal of Arthroplasty, 2007
- Two- to 9-Year Clinical Results of Alumina Ceramic-on-Ceramic THAClinical Orthopaedics and Related Research, 2006
- Alumina Ceramic-Ceramic Total Hip Arthroplasty using Computer-Assisted Surgical Navigation and a New Minimally Invasive Technique2004
- Ceramic-on-Ceramic Bearings in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2002
- New experience with alumina-on-alumina ceramic bearings for total hip arthroplastyThe Journal of Arthroplasty, 2002
- Alumina-on-Alumina Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2002
- Ceramic Femoral Head Retrieval DataClinical Orthopaedics and Related Research, 2000
- Modern Ceramic-on-Ceramic Total Hip Systems in the United StatesClinical Orthopaedics and Related Research, 2000
- Ceramic Bearing SurfacesClinical Orthopaedics and Related Research, 1999
- Long-term results of uncemented alumina acetabular implantsThe Journal of Bone and Joint Surgery. British volume, 1994