TomoGAN: low-dose synchrotron x-ray tomography with generative adversarial networks: discussion
- 12 February 2020
- journal article
- research article
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (3) , 422-434
Abstract
Synchrotron-based x-ray tomography is a noninvasive imaging technique that allows for reconstructing the internal structure of materials at high spatial resolutions from tens of micrometers to a few nanometers. In order to resolve sample features at smaller length scales, however, a higher radiation dose is required. Therefore, the limitation on the achievable resolution is set primarily by noise at these length scales. We present TomoGAN, a denoising technique based on generative adversarial networks, for improving the quality of reconstructed images for low-dose imaging conditions. We evaluate our approach in two photon-budget-limited experimental conditions: (1) sufficient number of low-dose projections (based on Nyquist sampling), and (2) insufficient or limited number of high-dose projections. In both cases, the angular sampling is assumed to be isotropic, and the photon budget throughout the experiment is fixed based on the maximum allowable radiation dose on the sample. Evaluation with both simulated and experimental datasets shows that our approach can significantly reduce noise in reconstructed images, improving the structural similarity score of simulation and experimental data from 0.18 to 0.9 and from 0.18 to 0.41, respectively. Furthermore, the quality of the reconstructed images with filtered back projection followed by our denoising approach exceeds that of reconstructions with the simultaneous iterative reconstruction technique, showing the computational superiority of our approach.Keywords
All Related Versions
Funding Information
- Office of Science (DE-AC02-06CH11357)
This publication has 38 references indexed in Scilit:
- Super-resolution: a comprehensive surveyMachine Vision and Applications, 2014
- Iterative Reconstruction Algorithm for CT: Can Radiation Dose Be Decreased While Low-Contrast Detectability Is Preserved?Radiology, 2013
- A comparative study of X-ray tomographic microscopy on shales at different synchrotron facilities: ALS, APS and SLSJournal of Synchrotron Radiation, 2012
- Iterative reconstruction methods in X-ray CTPhysica Medica, 2012
- Low-dose computed tomography image restoration using previous normal-dose scanMedical Physics, 2011
- Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CTMedical Physics, 2009
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Iterative Methods for Total Variation DenoisingSIAM Journal on Scientific Computing, 1996
- X-ray computed microtomography (μCT) using synchrotron radiation (SR)Progress in Biophysics and Molecular Biology, 1996
- A note on “very noisy≓ channelsInformation and Control, 1963