Early Neointimal Coverage and Vasodilator Response Following Biodegradable Polymer Sirolimus-Eluting vs. Durable Polymer Zotarolimus-Eluting Stents in Patients With Acute Coronary Syndrome
- 1 January 2015
- journal article
- research article
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (2) , 360-367
Abstract
Patients at high bleeding risk would benefit from a shorter dual antiplatelet therapy after PCI. Compared to first-generation devices, the design of newer generation drug-eluting stents may facilitate more rapid anatomical and functional healing of stented vessel based on thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution. Forty-four non-diabetic patients with acute coronary syndrome (ACS) and culprit lesion in the LAD were randomized to receive either biodegradable polymer sirolimus-eluting stent (BP-SES) or durable polymer zotarolimus-eluting stent (DP-ZES). Neointimal strut coverage was examined using optical coherence tomography, and vasodilator response on invasive thermodilution-derived coronary flow reserve (CFR) at 3-month follow-up. The primary endpoints were percent uncovered struts and CFR. A total of 425 cross-sections (4,897 struts) were analyzed in the BP-SES group, and 425 cross-sections (5,467 struts) in the DP-ZES group. The percent uncovered struts was lower in the BP-SES group compared with the DP-ZES group, both at strut level (3.9% vs. 8.9%, respectively, P0.05). In non-diabetic patients with ACS, BP-SES provided slightly better stent strut coverage at 3 months compared with DP-ZES, but neither stent was fully covered. No difference in vasodilator response was seen.Keywords
This publication has 25 references indexed in Scilit:
- Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable PolymerCirculation Journal, 2014
- Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysisThe Lancet, 2012
- In Vivo Optical Coherence Tomography of Very Late Drug-Eluting Stent Thrombosis Compared With Late In-Stent RestenosisCirculation Journal, 2012
- Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trialEuropean Heart Journal, 2011
- An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-studyEuropean Heart Journal, 2009
- Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent ThrombosisCirculation, 2009
- Impact of polymer hydrophilicity on biocompatibility: Implication for DES polymer designJournal of Biomedical Materials Research Part A, 2008
- Local vascular dysfunction after coronary paclitaxel-eluting stent implantationInternational Journal of Cardiology, 2007
- Pathological Correlates of Late Drug-Eluting Stent ThrombosisCirculation, 2007
- Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantationEuropean Heart Journal, 2005