ANALYSIS OF THE WIDTH OF PROTECTION ZONE NEAR A WATER SUPPLY NETWORK
Open Access
- 1 January 2019
- journal article
- research article
- Published by Walter de Gruyter GmbH in Architecture, Civil Engineering, Environment
- Vol. 12 (1) , 123-128
Abstract
A protection zone near the water supply network belongs to the proposals of limiting negative results of potential breakages of buried water pipes. Water leaking from a damaged pipe can create swallow holes or hollows, dangerous especially in the urban areas. The proposed zone is an area on the soil surface along a buried water network, where the outflow of water could be expected after a potential failure of the pipe. The infrastructure in this zone should be carefully planned to limit the social, economic and environmental costs in the case of leakage. The investigations included laboratory tests of a buried water pipe breakage for different cases of leak areas and values of hydraulic pressure head in a pipe as well as analysis of the obtained results and determination of a protection zone for the investigated cases on the basis of tolerance limits. The calculated values of the zone width (5 m if operating pressure is lower than 0.4 MPa, and 7 m otherwise) occurred high, mainly because of the high dispersion of the laboratory tests results. Moreover, we recommended the values of tolerance level to be assumed in calculations.Keywords
This publication has 19 references indexed in Scilit:
- Distance and time of water effluence on soil surface after failure of buried water pipe. Laboratory investigations and statistical analysisEksploatacja i Niezawodność – Maintenance and Reliability, 2016
- Monitoring of water distribution system effectiveness using fractal geometryBulletin Of The Polish Academy Of Sciences-Technical Sciences, 2015
- Locating Pipe Bursts in a District Metered Area Via Online Hydraulic ModellingProcedia Engineering, 2015
- Neural network approach for failure rate predictionEngineering Failure Analysis, 2015
- Computational Intelligence for Urban Infrastructure Condition Assessment: Water Transmission and Distribution SystemsIEEE Sensors Journal, 2014
- Experimental investigations of zones of leakage from damaged water network pipes2014
- Including leakage in network models: an application to calibrate leak valves in EPANETJournal of Water Supply: Research and Technology—AQUA, 2014
- Accuracy Assessment of Leak Localisation Method Depending on Available MeasurementsProcedia Engineering, 2014
- Geostatistical techniques for approximate location of pipe burst events in water distribution systemsJournal of Hydroinformatics, 2013
- Evaluating leakage potential in water distribution systems: a fuzzy-based methodologyJournal of Water Supply: Research and Technology—AQUA, 2012