Timely multithreat biological, chemical and nuclide detection: a platform, a metric, key results

Authors:
  • MDMark S. Derzon
    Mark S. Derzon
  • MHMatthew M. Hopkins
    Matthew M. Hopkins
  • PGPaul C. Galambos
    Paul C. Galambos
  • KAKomandoor E. Achyuthan
    Komandoor E. Achyuthan
  • CBChris J. Bourdon
    Chris J. Bourdon
  • IBIgal Brener
    Igal Brener
  • CJConrad D. James
    Conrad D. James
  • JMJaime L. McClain
    Jaime L. McClain
  • DPDavid W. Peterson
    David W. Peterson
  • KRKamyar Rahimian
    Kamyar Rahimian
  • JTJerylin A. Timlin
    Jerylin A. Timlin
  • JCJames S. Cullor
    James S. Cullor

Abstract
Terrorism has been called 'war in the 21st century' (Barnett). Metrics are needed to quantify changes in threat state as well as system design trade-offs that weight the time required for accurate identification against the threat detection sensitivity. We present an adaptable agent-detection-platform capable of sensing multiple threat agents (chemical, biological and nuclear) simultaneously in diverse media and a performance model of this detection platform. A performance metric 'Time-To-Identify' (TTI); the time required to identify the presence of a given target analyte is presented. Experimental results that illustrate the new technologies required by this platform are presented. The model and metric predict the detection platform's sensitivity and speed for several CONcepts of OPeration (CONOP): (1) agent detection (chemical, viral or bacterial) in a 1 ml clinical sample, (2) botulinum toxin detection in milk and (3) pathogen detection in airplane cabin air.