The Application of Terahertz Technology in Corneas and Corneal Diseases: A Systematic Review
Open Access
- 8 January 2025
- journal article
- review article
- Published by MDPI AG in Bioengineering
- Vol. 12 (1) , 45
Abstract
Terahertz (THz) waves reside in the electromagnetic spectrum between the microwave and infrared bands. In recent decades, THz technology has demonstrated its potential for biomedical applications. With the highly unique characteristics of THz waves, such as the high sensitivity to water and optimal spatial resolution coupled with the characteristics of the human cornea, such as its high water content, THz technology has been explored as a potential modality to assess corneas and corneal diseases. This systematic review provides an overview of the characteristics of THz waves, the safety profile of THz technology in the field of ophthalmology, and its clinical applications, including the objective evaluation of the corneal hydration, tear film, dry eye disease, corneal endothelium, corneal elasticity, and scarring. The paper also presents our viewpoint on the present challenges and future directions of THz technology prior to its broader integration into clinical practice.Keywords
Funding Information
- Singhealth DUKE-NUS AMC—A*STAR Healthcare Translation Partnership (05 FY2023 HTP P1 01–A1)
This publication has 81 references indexed in Scilit:
- Terahertz imaging technology for localization of cancer tumours: a technical reviewMultimedia Tools and Applications, 2023
- In vivo sensing of rabbit cornea by terahertz technologyJournal of Biophotonics, 2021
- Cell signaling in regulation of the barrier integrity of the corneal endotheliumExperimental Eye Research, 2012
- Molecular mechanisms underlying the corneal endothelial pumpExperimental Eye Research, 2012
- Prevalence of Dry Eye Disease in an Elderly Korean PopulationArchives of Ophthalmology (1950), 2011
- Origin of the fast relaxation component of water and heavy water revealed by terahertz time-domain attenuated total reflection spectroscopyChemical Physics Letters, 2008
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Ultrasonic model and system for measurement of corneal biomechanical properties and validation on phantomsJournal of Biomechanics, 2007
- Hydration and Transparency of Corneal StromaArchives of Ophthalmology (1950), 1966
- The diagnosis of the depth of burningBritish Journal of Surgery, 1953