Evaluation of structural and ultrastructural changes in thyroid and parathyroid glands after near infrared irradiation: study on an animal model
Authors:
Open Access
Abstract
Intraoperative identification of parathyroid glands is a tough task for surgeons performing thyroid or parathyroid surgery, because the small size, color and shape of these glands hinder their discrimination from other cervical tissues. In 2011, Paras described the autofluorescence of parathyroid glands, a property that could facilitate their intraoperative identification. Parathyroid glands submitted to a 785 nm laser beam emit fluorescence in the near infrared range, with a peak at 822 nm. As the intrinsic properties of secretory tissues may be affected by the exposure to the near infrared light, a situation that could preclude their intraoperative utilization, the authors compared the structural and ultra-structural patterns of rat’s thyroid and parathyroid glands submitted to irradiation replicating the conditions that allow their intraoperative identification, with those of non irradiated animals. Twenty-four Wistar rats were divided into six groups: animals of Groups 1, 3 and 5 were submitted under general anesthesia to direct irradiation of the cervical area with a 780 nm LED light for 3 minutes through a cervical incision, and animals of Groups 2, 4 and 6 were submitted to cervical dissection without irradiation. Animals of were euthanized immediately (Groups 1 and 2), at Day 30 (Groups 3 and 4) at and at Day 60 (Groups 5 and 6) and thyroid and parathyroid glands were removed: one lobe was prepared for conventional pathological examination and the other lobe for electron microscopy observed by three experienced pathological experts. Twenty-four samples were prepared for conventional histology and there were no alterations reported in any group. Due to technical problems, only 21 samples were observed by electron microscopy and there were no differences in the ultrastructure of parathyroid and thyroid glands, namely the nuclear pattern, mitochondria, endoplasmic reticulum or secretory granules, in any of the groups. These results confirm the innocuity of near infrared irradiation’, allowing its intraoperative utilization.Keywords
This publication has 27 references indexed in Scilit:
- Effect of Three Different Protocols of Low-Level Laser Therapy on Thyroid Hormone Production After Dental Implant Placement in an Experimental Rabbit ModelPhotomedicine and Laser Surgery, 2014
- A novel optical approach to intraoperative detection of parathyroid glandsSurgery, 2013
- An Update on the Structure of the Parathyroid GlandThe Open Anatomy Journal, 2013
- Assessment of the systemic effects of low-level laser therapy (LLLT) on thyroid hormone function in a rabbit modelInternational Journal of Oral and Maxillofacial Surgery, 2013
- Anatomy and Embryology of the Thyroid and Parathyroid GlandsSeminars in Ultrasound, CT and MRI, 2012
- Near-infrared autofluorescence for the detection of parathyroid glandsJournal of Biomedical Optics, 2011
- Evaluation of Low Intensity Laser Effects on the Thyroid Gland of Male MicePhotomedicine and Laser Surgery, 2005
- Cell and tissue autofluorescence research and diagnostic applications2005
- Measurement of the penetration depths of red and near infrared light in human “ex vivo” tissuesJournal of Photochemistry and Photobiology B: Biology, 2000
- Anatomy, Histology, and Ultrastructure, Parathyroid, Mouse1996