Screening for New-Onset Diabetes After Kidney Transplantation
Authors:
- Christopher J. YatesCYChristopher J. Yates
- Spiros FourlanosSFSpiros Fourlanos
- Peter G. ColmanPCPeter G. Colman
- Solomon J. CohneySCSolomon J. Cohney
- 27 October 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Transplantation
- Vol. 96 (8) , 726-731
Abstract
The sensitivity of fasting plasma glucose (FPG) in screening for new-onset diabetes after transplantation (NODAT) has been questioned, particularly in the presence of moderate-dose prednisolone, where peak plasma glucose occurs 7 to 8 hr after administration. Oral glucose tolerance testing (OGTT) has been mooted as an alternative but is inconvenient for patients. We compared sensitivity of screening tests for NODAT at 6 weeks, 3 months, and 12 months after kidney transplantation in recipients receiving prednisolone, mycophenolate, and tacrolimus. At 6 weeks, NODAT (capillary blood glucose [CapBG] ≥11.1 mmol/L, FPG ≥7.0 mmol/L, 2-hr plasma glucose ≥11.1 mmol/L, or glycated hemoglobin [HbA1c] ≥6.5%) was detected in 46% with CapBG versus 12% with OGTT (P=0.013), 4% with HbA1c (P<0.001), and 0% with FPG (P<0.001; n=26). At 3 months, NODAT was present in 14% with HbA1c versus 20% with OGTT (P=0.600) and 2% with FPG (P=0.059; n=50), whereas, at 12 months, NODAT was found in 4% with HbA1c versus 6% with OGTT (P=1.00) and 2% with FPG (P=0.618; n=51). Combining 3- and 12-month data, OGTT recorded NODAT in 14% and impaired glucose tolerance in 28%, whereas HbA1c detected NODAT in 10% and impaired glucose tolerance (from ≥5.7 to <6.5%) in 51%. Employing HbA1c as a screening test and reserving OGTT for those with impaired glucose tolerance would detect NODAT with a sensitivity more than 94%, avoiding the need for OGTT in 49% of patients. This study confirms the inadequacy of FPG screening for NODAT in the first 6 weeks after transplantation, at which time 4 p.m. CapBG also outperformed OGTT. From 3 months, HbA1c had similar sensitivity to OGTT and represents a convenient alternative.Keywords
This publication has 19 references indexed in Scilit:
- Novel views on new-onset diabetes after transplantation: development, prevention and treatmentNephrology Dialysis Transplantation, 2013
- Complications associated with new-onset diabetes after kidney transplantationNature Reviews Nephrology, 2011
- The association of early post-transplant glucose levels with long-term mortalityDiabetologia, 2011
- Diagnostic Application of the A1c Assay in Renal DiseaseJournal of the American Society of Nephrology, 2010
- International Expert Committee Report on the Role of the A1C Assay in the Diagnosis of DiabetesDiabetes Care, 2009
- Fasting Plasma Glucose and Glycosylated Hemoglobin in the Screening for Diabetes Mellitus After Renal TransplantationTransplantation, 2009
- Medical Management of Hyperglycemia in Type 2 Diabetes: A Consensus Algorithm for the Initiation and Adjustment of TherapyDiabetes Care, 2009
- Guidelines for the treatment and management of new‐onset diabetes after transplantation1Clinical Transplantation, 2005
- Diabetes control and complications: the role of glycated haemoglobin, 25 years onDiabetic Medicine, 2003
- NEW-ONSET DIABETES AFTER TRANSPLANTATION: 2003 INTERNATIONAL CONSENSUS GUIDELINES1Transplantation, 2003