Concentrating membrane proteins using ultrafiltration without concentrating detergents
- 8 March 2016
- journal article
- research article
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 113 (10) , 2122-2130
Abstract
Membrane proteins (MPs) are of rapidly growing interest in the design of pharmaceutical products, novel sensors, and synthetic membranes. Ultrafiltration (UF) using commercially available centrifugal concentrators is typically employed for laboratory‐scale concentration of low‐yield MPs, but its use is accompanied by a concomitant increase in concentration of detergent micelles. We present a detailed analysis of the hydrodynamic processes that control detergent passage during ultrafiltration of MPs and propose methods to optimize detergent passage during protein concentration in larger‐scale membrane processes. Experiments were conducted using nonionic detergents, octyl‐β‐D glucoside (OG), and decyl‐β‐D maltoside (DM) with the bacterial water channel protein, Aquaporin Z (AqpZ) and the light driven chloride pump, halorhodopsin (HR), respectively. The observed sieving coefficient (So), a measure of detergent passage, was evaluated in both stirred cell and centrifugal systems. So for DM and OG increased with increasing filtrate flux and decreasing shear rates in the stirred cell, that is, with increasing concentration polarization (CP). Similar effects were observed during filtration of MP‐detergent (MPD) micelles. However, lower transmission was observed in the centrifugal system for both detergent and MPD systems. This is attributed to free convection‐induced shear and hence reduced CP along the membrane surface during centrifugal UF. Thus to concentrate MPs without retention of detergent, design of UF systems that promote CP is required. Biotechnol. Bioeng. 2016;113: 2122–2130.Keywords
Funding Information
- National Science Foundation (NSF MCB 1359634)
This publication has 32 references indexed in Scilit:
- Direct Observation of the Formation of Surfactant Micelles under Nonisothermal Conditions by Synchrotron SAXSJournal of the American Chemical Society, 2013
- The effects of shear flow on protein structure and functionBiopolymers, 2011
- Computational analysis of membrane proteins: the largest class of drug targetsDrug Discovery Today, 2009
- Chapter 9 Concentration of Proteins and Removal of Solutes2009
- Phase Separation in the Isolation and Purification of Membrane ProteinsBioTechniques, 2007
- Spectrophotometric Determination of Protein ConcentrationCurrent Protocols in Protein Science, 2003
- Comparison of Small-Angle Scattering Methods for the Structural Analysis of Octyl-β-maltopyranoside MicellesThe Journal of Physical Chemistry B, 2002
- Use of Micellar-Enhanced Ultrafiltration at Low Surfactant Concentrations and with Anionic–Nonionic Surfactant MixturesJournal of Colloid and Interface Science, 1999
- Particle size measurement: the equivalent spherical diameterProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1988
- Mass transfer to a rotating fluid. Part II. Transport from the base of an agitated cylindrical tankAIChE Journal, 1972