Accuracy Evaluation of Indirect Bonding Techniques for Clear Aligner Attachments Using 3D-Printed Models: An In Silico and Physical Model-Based Study
Authors:
- Cosmina Raluca FratilaCFCosmina Raluca Fratila
- Luis Óscar Alonso-EzpeletaLALuis Óscar Alonso-Ezpeleta
- Manuel Poveda-SaenzMPManuel Poveda-Saenz
- Giovanni GiovanniniGGGiovanni Giovannini
- Ana Belén Lobo-GalindoALAna Belén Lobo-Galindo
- Javier Flores-FraileJavier Flores-Fraile
- Álvaro Zubizarreta-MachoÁlvaro Zubizarreta-Macho
Open Access
Abstract
An inaccurate bonding procedure of the attachments related to clear aligner systems could influence the predictability of tooth movement The aim of this study was to compare the positioning reliability of horizontal and vertical orthodontic clear aligner attachments. Materials and Methods: A total of 70 horizontal and 70 vertical orthodontic clear aligner attachments were bonded to five upper and five lower experimental anatomically based acrylic resin models with 14 clinical crowns each. The experimental anatomically based acrylic resin models were randomly distributed to the following study groups: Group A—horizontal orthodontic clear aligner attachments (n = 70) (HORIZONTAL) and Group B—vertical orthodontic clear aligner attachments (n = 70) (VERTICAL). Afterward, the orthodontic clear aligner attachments were digitally planned using orthodontic planning software, and orthodontic templates were manufactured by thermoforming on 3D-printed models in trilayer glycol-modified polyethylene terephthalate. Both horizontal and vertical orthodontic clear aligner attachments were put through an intra-oral scan to obtain a postoperative digital image, and PAPver, PCPver, PMVver, AUver, Alver, PPMhor, PPDhor, PMVhor, AMhor and ADhor cephalometric parameters were analyzed using a t-test or a non-parametric Mann–Whitney–Wilcoxon test. Results: The results showed that all cephalometric parameters showed statistically significant differences (p < 0.05) between the accuracy of the indirect bonding technique for horizontal and vertical orthodontic clear aligner attachments, except for the PAPver (p = 0.6079) and PMVhor (p = 0.5001) cephalometric parameters. Conclusions: The vertical orthodontic clear aligner attachments are more accurate than the horizontal orthodontic clear aligner attachments through the indirect bonding technique.Keywords
This publication has 43 references indexed in Scilit:
- The effect of layer thıckness on the accuracy of the dıfferent ın-house clear alıgner attachmentsClinical Oral Investigations, 2023
- Effectiveness of the Attachment Design and Thickness of Clear Aligners during Orthodontic Anterior Retraction: Finite Element AnalysisEuropean Journal of Dentistry, 2023
- Effect of trimming line design and edge extension of orthodontic aligners on force transmission: An in vitro studyJournal of Dentistry, 2022
- Emerging insights and new developments in clear aligner therapy: A review of the literatureAJO-DO Clinical Companion, 2022
- ‘Invisible’ orthodontics by polymeric ‘clear’ aligners molded on 3D-printed personalized dental modelsRegenerative Biomaterials, 2022
- Effects of different aligner materials and attachments on orthodontic behaviorJournal of Dental Sciences, 2021
- Clear aligner hybrid approach: A case reportJournal of the World Federation of Orthodontists, 2020
- Efficacy of a Copper–Calcium–Hydroxide Solution in Reducing Microbial Plaque on Orthodontic Clear Aligners: A Case ReportEuropean Journal of Dentistry, 2019
- Which orthodontic appliance is best for oral hygiene? A randomized clinical trialAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2018
- Les appareils orthodontiques invisibles et presque invisiblesL'Orthodontie Française, 2014