Mitigation of spectral mis-registration effects in imaging spectrometers via cubic spline interpolation.
Authors:
Open Access
- 15 September 2008
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (20) , 15366-15374
Abstract
The effects of spectral curvature (smile) on the co-registration of measured radiance spectra were analyzed for a dispersive imaging spectrometer. The spectra measured by the imaging spectrometer with spectral curvature were re-sampled using cubic spline Interpolation to mitigate the mis-registration of spectral radiance measurement. After correction, the co-registration of measured radiance spectra is distinctly improved.Keywords
This publication has 10 references indexed in Scilit:
- Spectral calibration and atmospheric correction of ultra-fine spectral and spatial resolution remote sensing data. Application to CASI-1500 dataRemote Sensing of Environment, 2007
- Refinement of wavelength calibrations of hyperspectral imaging data using a spectrum-matching techniqueRemote Sensing of Environment, 2004
- On-orbit radiometric and spectral calibration characteristics of EO-1 Hyperion derived with an underflight of AVIRIS and in situ measurements at Salar de Arizaro, ArgentinaIEEE Transactions on Geoscience and Remote Sensing, 2003
- Ocean PHILLS hyperspectral imager: design, characterization, and calibrationOptics Express, 2002
- Calibration of SeaWiFS I Direct techniquesApplied Optics, 2001
- A generalized approach to the vicarious calibration of multiple Earth observation sensors using hyperspectral dataRemote Sensing of Environment, 2001
- Hyperspectral imagers for current and future missions2000
- Imaging Spectroscopy and the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)Remote Sensing of Environment, 1998
- Spectral calibration requirement for Earth-looking imaging spectrometers in the solar-reflected spectrumApplied Optics, 1998
- Optical concepts for high-resolution imaging spectrometers1995